How many programmed cells of a NAND flash memory the radiation environment deprograms between one program (or refresh) and the next read: the floating-gate prompt charge-loss model of JPL Publication 16-9, with its published fits to the Samsung 8 Gb SLC part, carried over CREME96 ion spectra, the dose at the die and the measured proton cross sections, then through the error-correcting code.
Expected bit errors per die at the read, for every interval length from one day to ten years, in the environment above. Dose is scaled with the interval from the value entered; events are added at the counts entered whatever the interval. The curves use the single-hit form of the model, which agrees with the full form to better than one percent wherever hits per gate are rare (the tiles use the full form).
The single-hit (SEU-like) cross section per programmed gate, at zero dose, after the dose entered, and after 150 krad(Si), the dose at which the conservative set's DEF was fitted. The two points are the post-150-krad measurements quoted in TNS 2017: the Ar point the DEF was fitted to, and the Ne point taken at a fluence too large for a cross section to be defined, which the fit excluded and which the model does not reproduce.
Single-hit deprogramming rate per programmed gate per day in each built-in environment, with the parameter set and dose state above, and the strong hits (direct gate hits) per gate per day that drive it. Event rows are rates during the event.
The full model at one LET: the expected number of deprogrammed cells in a device of the cells entered above, all programmed, after the fluence given, with the prior dose given. This is the calculation that reproduces the large-fluence curves of TNS 2017 Fig. 6 when the Device A or Device B set is chosen with its beam.
"May be low" means the true number is likely above the prediction; "may be high" the reverse; "either way" the direction depends on the device or the environment.
A programmed floating gate holds charge; an ion that crosses the gate itself (a strong interaction, cross section σS,sat per gate) removes a share L/b₁ of the mean critical charge, L being its LET in SiO₂; an ion that passes near the gate (a weak interaction, σW,sat) removes L/b₂ by charging the surrounding oxide, which compensates part of the stored charge. Dose removes μ·DEF·D·(σS/b₁ + σW/b₂) deterministically, with μ = 6.2415 × 10⁴ MeV per mg per rad. The losses add; the gate reads as deprogrammed once they exceed its critical loss, which varies from gate to gate as a Weibull distribution of shape k. With Poisson hit counts, for one LET:
Over a spectrum the summed loss is a compound Poisson variable; the page evaluates its distribution exactly on a loss grid (Panjer recursion), so many light ions, a few heavy ones and the dose shift are all in one calculation. Where hits per gate are rare, this reduces to fluence times the single-hit cross section plus the dose-only fraction, and the page shows both.
No parameter is invented: the sets are the published tables, the cross sections the published values, the spectra the site's CREME96 runs. The Conclusions card lists, for this run, which of these is measured, assumed or missing, and which way each one pushes the number.
This page is a planning aid. Its numbers come from the published model and fits, the environment chosen and the dose entered, carry the assumptions listed under Conclusions, and are not a qualification result for any part or mission. Nothing on it has been reviewed by any organization.
The mechanism behind the model above. A programmed cell holds electrons on a floating gate, or in a nitride layer, that raise its threshold voltage above a read reference; for the nanoseconds an ion track lives, the dielectrics around that charge conduct along the track and part of the charge leaves. If the threshold falls below a reference the cell reads wrong, and an erased cell, with nothing above the reference to lose, does not care. Drag to turn the string and step through the strike, the conductive path, the loss and the read, by the three routes the model adds: one heavy ion, many light ions, and dose; the full page carries the explanation, the levels and Gray code, the model and the references.