What do the radiation test standards require, and why?
A requirement without its reasoning gets followed wrongly: people skip the anneal step, qualify at one gate bias, or read a wear-out derating table as though it covered single events. Below the standards is a catalog of radiation test data sources, including the ones behind paywalls and logins, because knowing what exists matters even when you cannot reach it.
Every designation, revision and access term below was checked against the issuing body or the document itself in September 2026, and where that check failed the entry says so rather than guessing.
The reasoning
Why the numbers are the numbers
Every convention in this field started as somebody's reasoning, and most of that reasoning is still written down in the primary documents. It just does not travel with the number. These entries go back to the source and reconstruct it: what the value is, which clause states it, what physical or statistical argument produced it, and which paper the standard or its authors cite as the origin. Where a document states a rule and gives no reason, the entry says so instead of supplying one. Searching filters these along with everything else, so a query for or or lands here.
Why is the heavy ion test fluence 10,000,000 ions per square centimeter?1e7 ions/cm2It is where the smallest cross section you want to be able to exclude meets the largest total dose you can afford to put into the part.
The fluence is set from below by statistics. If a part is irradiated and nothing happens, the result is not "the cross section is zero", it is "the cross section is below some bound". For a Poisson process with no observed events, that bound is a constant divided by the fluence. JESD57A writes it as 3.7 divided by the fluence of no errors times cos(theta), the 3.7 being the upper end of a central 95 percent Poisson interval (97.5 percent one sided; 3.0 would be 95 percent one sided). At 1e7 ions/cm2 that gives 3.7e-7 cm2, which is 37 square micrometers per device: on a memory die that is tens to hundreds of bit cells, on a discrete a small fraction of the die. Run only 1e5 ions/cm2 and the bound is 3.7e-5 cm2, 3,700 square micrometers, which still excludes the larger latchup cross sections but says little about upset.
The fluence is set from above by total dose. A heavy ion run is also a dose run, and the dose scales with LET. Using 1.602e-5 rad(Si) per unit of LET in MeV cm2/mg per ion/cm2: at LET 10, a fluence of 1e7 delivers about 1.6 krad(Si); at LET 37 about 5.9 krad; at LET 60 about 9.6 krad; at LET 85 about 13.6 krad. ASTM F1192 makes exactly this point, that the usual heavy ion fluence corresponds to kilorad dose levels in the part, and that the accumulated dose can change the effect being measured. So the ceiling is not a matter of beam time, it is that a part irradiated much past 1e7 at high LET is no longer the part that was put in the beam.
Those two constraints cross near 1e7, which is why the number has survived from ASTM F1192 into JESD57A and into ESCC 25100 essentially unchanged. It is a compromise, not a physical constant. Above the onset threshold, where events are plentiful, JESD57A explicitly says 1e6 or 100 observed events will do, because there the precision comes from the event count rather than from the fluence.
What this does not license. A clean run to 1e7 bounds the cross section, it does not bound the threshold. A part with a real onset just above the tested LET and a cross section of 1e-6 cm2 will pass 1e7 at the LET below it and still fail on orbit. The fluence answers how small, not how close.
Where it is written down
- ASTM F1192-11(2018), 4.4.8 and 4.4.9. States the minimum fluence is whatever is needed to turn a no-upset result into an acceptable upper bound at a stated confidence, and that 1e7 will often meet that. 4.4.9 requires the accumulated dose to be recorded and warns it may act differently from a uniform gamma dose.
- ASTM F1192-11(2018), 6.3.2. States that the usual heavy ion fluence of 1e6 to 1e7 ions/cm2 corresponds to kilorad dose levels, and that this dose may alter the effect being monitored.
- JESD57A, 5.2.11 and 5.2.12. Gives the 3.7 over fluence relation for a null result, cites ASTM for the historical adequacy of 1e7, and requires accumulated dose to be recorded and compared against the device dose tolerance. For burnout and gate rupture it gives 5e5 as a minimum for large discretes and 1e7 for small integrated devices.
- ESCC Basic Specification No. 25100, 4.3. Recommends 1e7 ions/cm2 for heavy ions on an insensitive device, and notes that the accompanying total dose may force fresh samples.
Cited as the origin
- Ricker, W. E., 1937, The concept of confidence or fiducial limits applied to the Poisson frequency distribution. Journal of the American Statistical Association 32(198), 349
- Petersen, E. L., 1997, Single Event Analysis and Prediction. IEEE NSREC Short Course, Snowmass
Why 3.7 for a null result, when other people use 3.0 or 2.3?3.7 vs 3.0 vs 2.3All three are the same Poisson calculation. They differ only in the confidence level and in whether the interval is one sided or two sided.
For a Poisson process with zero observed events, the upper limit on the mean at a one sided confidence level CL is minus the natural log of one minus CL. That gives 2.303 at 90 percent, 2.996 at 95 percent and 4.605 at 99 percent. This is where the familiar 2.3 and 3.0 come from.
JESD57A and ESCC 25100 instead use the chi-square form, half of the inverse chi-square at 0.5 plus CL over 2 with 2N plus 2 degrees of freedom. At N equal to zero and CL equal to 95 percent this evaluates to 3.689, which both documents round to 3.7. That is not a different statistical model, it is the same Poisson bound evaluated at the upper tail of a two sided 95 percent interval, which is the 97.5 percent one sided point. So 3.7 is simply more conservative than 3.0 by the amount that a two sided convention costs.
The practical consequence is that two laboratories can report different upper bounds on the same clean run and both be right. When comparing a published bound against your own, check which constant was used before concluding that one part is harder than another. The ratio between the 90 percent one sided and the JEDEC convention is 1.6, which is easily large enough to flip a margin argument.
What this does not license. None of these constants make a null result into evidence of hardness. They convert one number, the fluence, into another number, a bound. If the beam missed the sensitive area, or the part was in the wrong state, the bound is on nothing.
Where it is written down
- JESD57A, 5.2.11 and Annex A.10. Gives the 3.7 factor explicitly and states it bounds the cross section at 95 percent confidence when no events are measured. Annex A.10 gives the inverse chi-square expressions for the general case.
- JESD57A, note on plotting a no-event point. Directs that a null point be plotted with a unique symbol, a lower error bar of zero, and an upper bar of 3.7 times the cross section computed as though one event had occurred.
- ESCC Basic Specification No. 25100, Appendix A 1.6. Gives the same chi-square construction, citing JESD89 for the derivation, and states the same 3.7 value at zero events and 95 percent confidence.
Cited as the origin
- Ricker, W. E., 1937, The concept of confidence or fiducial limits applied to the Poisson frequency distribution. Journal of the American Statistical Association 32(198), 349
- Johnson, N. L., Kotz, S. and Kemp, A. W., 1993, Univariate Discrete Distributions, second edition. Wiley. Cited by Schwank, Shaneyfelt and Dodd for the confidence limit expressions
Why is the beam flux held between roughly 100 and 100,000 ions per square centimeter per second?1e2 to 1e5 ions/cm2/sToo high and the ions stop being independent single events; too low and the run does not finish.
The whole cross section formalism assumes each ion acts alone on an undisturbed device. Push the flux up and that assumption fails in several separate ways: two ions land in the same cell between reads and are counted as one multiple-bit upset; charge from one strike has not been swept out before the next arrives; the die heats; the dosimetry system, which is usually counting individual ions, saturates. ASTM F1192 calls these collective effects and allows higher flux only if each of them is shown not to matter.
There is a second, more mundane reason at the low end of the tester: dead time. ESCC 25100 puts a number on it and requires the flux to be low enough that the time the software spends reading, writing, resetting and logging stays below 20 percent of the active time, because an event that occurs during that window is never seen and the cross section comes out low. For latchup and for transients the guidance goes the other way and asks for lower flux still, so that events do not pile up and so that the part is not sitting in a latched state accumulating dose.
MIL-STD-750 Method 1080 approaches the same problem from the destructive side and caps the burnout event rate at 100 events per second, limited also by whatever the recording system can keep up with.
What this does not license. A flux inside the window does not prove independence for your part. A device with a long recovery time, a slow scrubber, or a deep sensitive volume can violate the single event assumption at a flux that is nominally legal.
Where it is written down
- ASTM F1192-11(2018), 4.4.7. Gives 1e2 to 1e5 ions/cm2/s as the normal range, for proper dosimetry and absence of collective effects, and permits higher flux only when dosimetry, tester limits, coincident upset effects and heating are accounted for.
- JESD57A, 5.2.10. Gives 1e3 to 1e5 ions/cm2/s as typical, and requires that the response reflect independent single ion strikes rather than accumulated effects of previous strikes. Notes lower flux may be needed to avoid overlapping transients and to protect the part during latchup testing.
- ESCC Basic Specification No. 25100, 3.1.2 and 4.2.2. Requires the accelerator to deliver from a few hundred to at least 1e5 ions/cm2/s, and for latchup requires the flux to keep tester dead time below 20 percent of active time.
- MIL-STD-750, Method 1080. Requires the flux to be adjusted so that burnout events do not exceed 100 per second, and to respect the recording rate of the test system.
Why do the standards ask for three parts, and what does three parts actually buy?2, 3, 4 or 5 partsThree is the smallest number that lets you see part to part disagreement at all. It does not characterize a distribution, and the documents do not claim it does.
The counts differ by document because they are answering different questions. ESCC 25100 asks for three samples and permits two for non-destructive effects, and requires three as a minimum for gate rupture and burnout so that compliance can be checked at each test condition. JESD234 asks for five for proton work on a homogeneous lot, and more when the lot is not homogeneous. JESD57A declines to give a number at all and says to use the largest sample practical, on the reasoning that confidence comes from events and devices together.
The stated justification everywhere is lot homogeneity, not statistics. ASTM F1192 says plainly that device to device variation in soft error response is generally small among parts built on the same masks and process, which is why a small sample is defensible, and then immediately warns that the flight parts may not be from that population because manufacturers change processes without notice.
For destructive effects that reasoning is much weaker, and the literature says so. The response variability work on commercial power MOSFETs found burnout onset voltages that were not merely scattered but bimodal, which is exactly the shape that a five part sample is least able to detect. The NASA avionics RHA guidelines make the same point in their appendix on sampling: a small sample drawn from a distribution with a low probability second mode will usually come back clean, and the clean result is not informative.
What this does not license. Three parts that agree tell you the three parts agree. They give essentially no information about the tail of the population, which is where destructive single event risk lives.
Where it is written down
- ESCC Basic Specification No. 25100, 4.1. Three samples recommended and two minimum for non-destructive effects; three minimum for destructive effects, to check pass compliance at each test condition; more recommended for better statistics.
- JESD234, 7.7.3. Recommends a minimum of five devices per test for a homogeneous single wafer or diffusion lot, and an expanded sample when the lot is not homogeneous.
- JESD57A, 5.2.2.2. Declines a fixed number, asks for the largest practical sample, and notes MIL-PRF-38535 Group E Subgroup 5 requires four.
- ASTM F1192-11(2018), 8.3.4. Argues small samples are acceptable because same-mask, same-process parts vary little, then warns that unannounced process changes break the equivalence.
- NASA/TM-20210018053, Appendix E. Discusses pathological distributions and states that sample sizes typical of lot acceptance testing are unlikely to sample a low probability second mode.
Cited as the origin
- George, J. S., Clymer, D. A., Turflinger, T. L., Manson, L. W., Stone, S., Koga, R., Beach, E., Huntington, K., Lauenstein, J.-M., Titus, J. and Sivertz, M., 2017, Response Variability in Commercial MOSFET SEE Qualification. IEEE Transactions on Nuclear Science 64(1), 317
- Wheatley, T. H., Wheatley, C. F. and Titus, J. L., 2001, Early lethal SEGR failures of VDMOSFETs considering nonuniformity in the rad-hard device distribution. IEEE Transactions on Nuclear Science 48, 2217
Why does the lid have to come off?lid removalBecause the horizontal axis of a cross section plot is the LET at the sensitive volume, and package material changes it by an unknown amount.
An ion loses energy continuously as it travels. Every millimeter of lid, every micron of coating, every layer of overglass shifts the ion down its stopping power curve, so the LET that reaches the die is not the LET the facility quoted, and the shift depends on material and thickness that are usually not documented. The result is not a small correction, it is an unknown correction, and the cross section curve it produces cannot be integrated against a mission spectrum.
The same logic sets the exception. If the ion range is much larger than everything in front of the die, the energy loss is small and calculable, and both ESCC 25100 and JESD57A allow testing through the package at high energy facilities on that basis. This is why high energy heavy ion beam lines exist and why they are worth the cost for parts that cannot be opened.
Backside thinning is the other branch of the same problem: flip chip parts and parts with heavy metallization cannot be reached from the front at all. JESD57A warns that thinning is not free, because it changes the substrate available for diffusion and it reduces the power the part can dissipate, so a thinned part is not electrically identical to the flight part.
What this does not license. A delidded part is mechanically and thermally different from a flight part. The delid is for the beam, and the electrical result should be checked afterwards, which is why ASTM requires the functional retest.
Where it is written down
- JESD57A, 6.2.1 and 6.2.2. Requires decapsulation to give the beam access to the chip face, waived for high energy facilities, and requires coatings to be removed or characterized. Covers die thinning and its side effects on charge collection and power dissipation.
- ASTM F1192-11(2018), 8.2.2. Requires all devices to be tested without lids except at very high energy, and requires a functional retest afterwards because lid removal can damage parts.
- ESCC Basic Specification No. 25100, 4.1. Requires delidding or thinning when energy loss in the package makes the LET at the die uncertain, and permits testing through the package when the range is much larger than the packaged device.
- MIL-STD-750, Method 1080. Requires delidding unless otherwise specified, and requires conformal coating to be removed where it compromises penetration.
Why does ion range matter, and where do 40 and 60 microns come from?30, 40 or 60 micronsLET is only constant over part of an ion track. The range requirement is there to keep the sensitive volume inside the flat part.
Quoting a single LET for an ion is a convenience that holds only while the stopping power is roughly constant. Near the end of the track it is not: the ion slows, the stopping power rises to the Bragg peak and then collapses. If the sensitive volume sits in that region, the effective LET across it is neither the surface value nor any single number, and the horizontal axis of the plot is fiction again.
The numbers follow from where the sensitive volume actually is. ESCC 25100 asks for 40 microns minimum for upset in CMOS logic, 60 microns for devices with thick sensitive volumes such as bipolar and JFET linear parts, and 60 microns specifically for latchup, because the parasitic thyristor that latches sits well below the surface circuitry. ASTM F1192 makes the same argument qualitatively, saying adequate range is especially crucial for latchup because the relevant junction is often buried deep, and cites 30 microns as a figure some test requirements specify. JESD57A gives no number and addresses the issue only through the requirement for near constant LET through the sensitive volume.
For power devices the effect is larger than for anything else, and it runs in the dangerous direction. The JPL gate rupture guideline shows short range ions overestimating failure voltages, with shifts as large as half the rated voltage between short and long range ions of nominally the same LET, on devices whose lightly doped drift region alone is 25 microns at 200 V and about 120 microns at 1000 V. A short range ion cannot traverse that region, so it deposits less charge where it counts and the part looks harder than it is.
What this does not license. Adequate range is necessary, not sufficient. It keeps the LET honest; it says nothing about whether the beam reached the right structure or whether the part was in its worst case state.
Where it is written down
- ESCC Basic Specification No. 25100, 4.2.6. 40 microns minimum range for heavy ion upset in CMOS logic; 60 microns for thick sensitive volumes; 60 microns at normal incidence for latchup unless a shorter range is shown sufficient to reach worst case sensitivity.
- ASTM F1192-11(2018), 4.4.10. States range is an important consideration, that adequate range is especially crucial for latchup because the junction is buried deep, and notes that some test requirements specify greater than 30 microns.
- JPL Publication 08-10, ion range section. Compares short range and long range ion data on the same high voltage device and states that short range ions overestimate failure voltage. Gives drift region depths by voltage class and recommends always choosing the longest range ion available at a given LET.
Cited as the origin
- Selva, L. E., Swift, G. M., Taylor, W. A. and Edmonds, L. D., 1999, On the role of energy deposition in triggering SEGR in power MOSFETs. IEEE Transactions on Nuclear Science 46, 1403
Why is effective LET equal to LET divided by cosine of the angle, and when does that stop being true?LET / cos(theta)It is a path length argument that holds for a thin, wide sensitive volume. It fails as soon as depth is comparable to width, which is most modern parts and all vertical power devices.
The derivation is one line. If the sensitive volume is a thin sheet, an ion arriving at angle theta crosses a path longer by one over cosine theta, so it deposits more charge in the same proportion, so it behaves like a normally incident ion of higher LET. That is the whole content of the effective LET concept.
Every assumption in it is now routinely violated. ASTM F1192 states the relation with the explicit condition that theta be below 60 degrees, and states that it breaks down when the lateral dimensions of the sensitive volume become comparable to its depth, which it names as the case for VLSI and other dense parts. JESD57A goes further and says effective LET should not be used for multiple bit upset or for gate rupture, and does not apply to any effect in a device whose sensitive volume is deep relative to its lateral extent.
For vertical power MOSFETs it is not merely inaccurate, it has the wrong sign. JESD57A notes that gate rupture sensitivity often decreases as the angle moves off normal, and MIL-STD-750 Method 1080 simply prohibits angling the die to produce effective LET values. The NASA avionics RHA guidelines state the same conclusion from the physics side: normal incidence to the dielectric is the worst case, so the effective LET concept is inadequate for gate and dielectric rupture.
What this does not license. Using angle to reach a high effective LET is a way of avoiding beam time, not a way of reaching a high LET. If the part fails the thin volume assumption, the tilted data belong on a different axis from the normal incidence data.
Where it is written down
- ASTM F1192-11(2018), 3.1.4 discussion. Gives the relation with the condition theta below 60 degrees, derives it from equal deposited charge in a wafer-thin volume, and states the breakdown condition for dense modern parts.
- JESD57A, 5.2.8.2 and Annex A.6.4. Permits effective LET for upset and latchup, prohibits it for multiple bit upset and gate rupture, and notes that vertical power MOSFET gate rupture sensitivity often falls with increasing angle.
- ESCC Basic Specification No. 25100, 4.2.7. States the relation is valid only when sensitive volume depth is small compared with lateral dimensions, and recommends cross checking against normal incidence results.
- MIL-STD-750, Method 1080. States that angling the die to produce effective LET values is invalid and should not be used, in both characterization and verification testing.
Cited as the origin
- Edmonds, L. D., 2002, A Method for Correcting Cosine-Law Errors in SEU Test Data. IEEE Transactions on Nuclear Science 49(3), 1522
- Petersen, E. L., Pickel, J. C., Smith, E. C., Rudeck, P. J. and Letaw, J. R., 1993, Geometrical Factors in SEE Rate Calculations. IEEE Transactions on Nuclear Science 40(6), 1888
Why is gate rupture worst at normal incidence, the opposite of upset?normal incidenceUpset is about charge collected along a track, so a longer track is worse. Rupture is about field across a thin dielectric at one point, so a track aimed straight down the axis is worse.
The two effects are driven by different integrals. Upset depends on the charge deposited within a collection volume, which grows with path length, so tilting the part helps the ion and hurts the device. Gate rupture depends on the transient field established across the gate dielectric by carriers moving in the underlying structure, and that is maximized when the ion track lies along the vertical axis of the cell, straight through the neck of the device and into the epitaxial layer beneath.
This is why the JPL gate rupture guideline requires the beam to be held within about 5 degrees of normal for rupture testing, and why it treats burnout as comparatively insensitive to angle. It is also why the RHA guidelines say plainly that normal incidence is the worst case for gate and dielectric rupture and that the effective LET concept is therefore inadequate for these mechanisms.
The practical trap is that a test campaign designed around upset habits will tilt the part to save beam time and will report a higher survival voltage than a normal incidence campaign would. Two datasets on the same part can disagree by a wide margin for this reason alone, with neither one wrong.
What this does not license. Normal incidence is worst case for the dielectric. It is not automatically worst case for every failure mode in the same part, which is why burnout and rupture are screened under different conditions.
Where it is written down
- JPL Publication 08-10, ion angle section. States that rupture is most likely when the ion path is parallel to the vertical axis of the device, requires testing within about 5 degrees of normal, and treats burnout as not sensitive to angular effects.
- NASA/TM-20210018053, single event types and heavy ion testing sections. States that particle incidence normal to the dielectric layer is the worst case for gate and dielectric rupture, which renders effective LET inadequate, and that the rectangular parallelepiped method is not valid for rupture, dielectric rupture or burnout.
- JESD57A, Annex A.6.4. Notes that vertical power MOSFET gate rupture sensitivity often decreases with increasing off-normal angle, so effective LET is not valid for these devices.
Cited as the origin
- Sexton, F. W., 2003, Destructive single-event effects in semiconductor devices and integrated circuits. IEEE Transactions on Nuclear Science 50(3), 603
- Sexton, F. W., Fleetwood, D. M., Shaneyfelt, M. R., Dodd, P. E., Hash, G. L., Krisch, K. S., Green, M. L., Weir, B. E. and Silverman, P. J., 1998, Precursor ion damage and angular dependence of single event gate rupture in thin oxides. IEEE Transactions on Nuclear Science 45, 2509
- Mouret, I., Allenspach, M., Schrimpf, R. D., Brews, J. R. and Galloway, K. F., 1994, Temperature and angular dependence of substrate response in SEGR. IEEE Transactions on Nuclear Science 41, 2216
Why are 15, 37, 60 and 75 MeV cm2/mg all quoted as immunity thresholds, and where does each one actually come from?LET 15, 37, 40, 60, 75Several independent arguments land near the same numbers. Recoil physics fixes 15 and contributes to 37. Mission risk tolerance and, for vertical power devices, what a beam line can actually deliver also produce 37. Only 60 and 75 are about the cosmic ray environment itself.
Start with the one that is genuinely physics. A high energy proton does not usually upset a part directly; it undergoes a nuclear reaction and the recoiling fragment does the ionizing, so the recoil spectrum sets a ceiling on the effective LET a proton can deliver. In silicon, recoils from 200 MeV protons reach roughly 11.5 to 15 MeV cm2/mg, which is the basis for the ESA rule that proton testing is required below a heavy ion threshold of 15. Modern parts are not only silicon, and tungsten, copper and tantalum in the interconnect and the package produce heavier recoils, which is why the NASA proton guidance uses about 37 as approximately the highest LET secondary obtainable from a 500 MeV proton and waives proton single event testing above it.
That recoil argument is one reason for 37 and it is the one most often quoted, but it is not the only reason and treating it as the whole story is misleading. A threshold is also a risk decision. The integrated risk on a mission scales with how many susceptible devices are flown and for how long, so a short mission with a modest parts count can accept a threshold that a long mission with thousands of susceptible devices cannot. 37 is frequently adopted on that basis alone, and it is a perfectly defensible basis, but it is a statement about the mission rather than about the part. The tiered structure of the program specifications, with one number treated as unacceptable, another as acceptable and a third as immune, is itself the evidence that these are risk tolerance choices. They should be expected to move when the mission does.
The third route to 37 has nothing to do with either argument, and it is the one that catches people out. For vertical power MOSFETs, effective LET is not valid: normal incidence is the worst case for gate rupture, and MIL-STD-750 Method 1080 prohibits angling the die to manufacture a higher effective LET. So the usual trick of tilting the part to reach a high LET number is unavailable. What is left is the LET the beam actually delivers at normal incidence, and that fights the other requirement these parts have, which is enough range to cross the drift region. Higher LET needs a heavier ion, and at a given energy per nucleon a heavier ion has less range in silicon, while the drift region runs from roughly 25 microns on a 200 V device to well over a hundred on a 1000 V one. Getting LET 75 and adequate range simultaneously at normal incidence is hard, and often not available at all. That is why LET 37 requirements appear for vertical power MOSFETs on missions whose reliability class would otherwise demand 75. It is a facility capability limit wearing the costume of a requirement, and it is the reason the higher energy per nucleon beam lines exist.
The environment numbers are unrelated to protons. They come from the shape of the cosmic ray LET spectrum, which falls very steeply once the abundant species are exhausted. Iron is the practical top of that distribution, and the TREE handbook singles out 100 MeV iron at about 27 MeV cm2/mg as representing the most highly ionizing particles commonly encountered. Allow for angle of incidence and a margin above iron and you arrive at the program thresholds: ECSS treats a part with no events at 60 as immune, and the USAF specification treats above 75 as acceptable.
These should not be mixed, and the practical consequence is that the same number carries different evidence depending on how it was arrived at. A part that clears 37 on the recoil argument has been argued safe against proton induced secondaries, and that says nothing about the direct cosmic ray flux above 37, which is small but not zero. A part that clears 37 because the mission is short has not been argued safe at all; the risk has been accepted, which is a different thing and should be recorded as such. A power MOSFET that clears 37 because that is what the beam could deliver has been tested to the limit of the available evidence, and the residual risk above 37 is simply unmeasured. When you inherit a part qualified to 37, the first question is which of these three it was.
What this does not license. These are screening thresholds for the usual mechanisms in the usual materials. The RHA guidelines note explicitly that parts with high atomic number materials in the active region can produce higher LET recoils, and that latchup has been seen in some devices only above 400 MeV proton energy. None of the three routes to 37 licenses the claim that a part is immune above 37; they license the claim that it was not tested there, that the residual risk was judged acceptable for a stated mission, or that no proton secondary should reach it. Write down which one you mean, because a later mission reusing the qualification will not be able to reconstruct it.
Where it is written down
- NASA/TM-20210018053, high energy proton and neutron testing section. States recoils in silicon from 200 MeV protons reach LET up to 11.5 to 15 MeV cm2/mg, that more than 99.7 percent of high LET recoils have range below 8 microns and so may not reach thick sensitive volumes, that ECSS requires proton testing below a heavy ion threshold of 15, and that parts below 37 to 40 are considered potentially proton susceptible. Notes heavier elements in the active region or packaging raise the achievable recoil LET.
- NASA proton single event effects guidance, August 2009. Sets the decision rule: no proton testing required when heavy ion testing shows no effects at a threshold of 37 or above, proton latchup testing required at or below 20, and a rate prediction with a large multiplier for the band between.
- ECSS-Q-ST-60-15C. Treats a device with no events at LET 60 at normal incidence as immune, and requires proton testing below a heavy ion threshold of 15.
- Transient Radiation Effects on Electronics Handbook, DNA-H-95-61, cosmic ray environment sections. Identifies the iron peak, gives 100 MeV iron at about 27 MeV cm2/mg as representing the most highly ionizing particles in the cosmic environment, and uses that as the minimum capability required of a simulation source.
- MIL-STD-750, Method 1080. States that angling the die to produce effective LET values is invalid and should not be used, which is what removes the usual route to a higher effective LET for vertical power MOSFETs and leaves the requirement bounded by what the beam delivers at normal incidence.
- JPL Publication 08-10, ion range section. Gives drift region depths by voltage class, roughly 25 microns at 200 V and over a hundred at 1000 V, and shows short range ions overestimating failure voltage. This is the constraint that competes with reaching a high LET at normal incidence.
- NASA/TM-20210018053, design margin section. Describes the radiation design margin approach as ad hoc and capable of both under and over specifying, and does not prescribe a numeric target, which is consistent with program LET thresholds being risk tolerance choices rather than physical constants.
Cited as the origin
- Adams, J. H. Jr., 1983, The variability of single event upset rates in the natural environment. IEEE Transactions on Nuclear Science 30(6), 4475
- Lauenstein, J.-M. et al., 2010, Interpreting Space-Mission LET Requirements for SEGR in Power MOSFETs. IEEE Transactions on Nuclear Science 57(6), 3443
- Schwank, J. R. et al., 2005, Effects of particle energy on proton-induced single-event latchup. IEEE Transactions on Nuclear Science 52(6), 2622
Why take cross section data out to LET 80 when the curve looks saturated at 40?LET 80, or 2x saturationBecause saturation has to be demonstrated, not assumed, and deep submicron parts stopped saturating where they used to.
A rate prediction integrates the cross section curve against the environment spectrum. If the curve is still rising where the data stop, the integral is truncated and the rate is understated. JESD57A therefore asks for data out to twice the saturation LET, and where that is not achievable, out to 80 MeV cm2/mg, which is close to the practical limit of most heavy ion facilities.
The reason this became a requirement rather than an aspiration is that highly scaled parts often do not show a clean plateau at all. As cell dimensions shrink, ions that were once well past saturation begin to upset neighboring cells, so the measured cross section per device keeps climbing. A curve that looks flat over a narrow LET window can turn out to have simply been sampled coarsely.
JESD57A also asks for intermediate points at specific fractions of the maximum cross section, and gives a different reason for each: about 75 to 80 percent to constrain the Weibull shape, 50 percent for the median critical charge, 25 percent for a quick figure of merit rate estimate, and 10 percent for comparison against older data and proton parameterizations. Six well defined points is the stated minimum for a fit with any predictive value.
What this does not license. Reaching 80 does not make the fit trustworthy. A Weibull through four points at low LET and one at high LET satisfies the letter of the requirement and constrains almost nothing.
Where it is written down
- JESD57A, 7.6.2. Requires data to twice the saturation LET, or to LET 80 in silicon where that is not possible, specifies a four parameter Weibull fit with a minimum of six well defined points, and gives the purpose of each intermediate fraction of the saturated cross section.
- ESCC Basic Specification No. 25100, 4.3. Requires the response curve to span from threshold to saturated cross section and recommends about five exposures to plot it.
Cited as the origin
- Petersen, E. L., Pickel, J. C., Adams, J. H. Jr. and Smith, E. C., 1992, Rate Prediction for Single Event Effects, a Critique. IEEE Transactions on Nuclear Science 39(6), 1577
Why does the part sit inside a lead and aluminum box during a cobalt 60 total dose test?1.5 mm Pb over 0.7 mm AlTo restore charged particle equilibrium. Without it, low energy scattered photons deposit a locally enhanced dose that the dosimeter does not see and the part does.
A cobalt 60 cell is not a clean 1.25 MeV field. Photons scatter off the source housing, the walls, the fixture and the part itself, producing a low energy tail. Low energy photons interact strongly through the photoelectric effect, whose cross section rises steeply with atomic number, so at an interface between a high atomic number material and a low one the secondary electron population is out of balance. Near the gold or tungsten of a package, or the metallization of the die, the silicon and the gate oxide can receive substantially more dose than the free field reading implies. This is dose enhancement, and it means the number written in the test report is wrong in an unknown direction.
The lead and aluminum container fixes this by filtering the low energy tail before it reaches the part, and by supplying enough material for secondary electron equilibrium to be established. MIL-STD-883 Method 1019, MIL-STD-750 Method 1019 and ESCC 22900 all specify the same construction: a minimum of 1.5 mm of lead surrounding an inner shield of at least 0.7 mm of aluminum. The lead is the filter and the aluminum is there so that the electrons entering the part come from a low atomic number material rather than from the lead itself. All three documents state the purpose in the same terms, that the arrangement produces approximate charged particle equilibrium for silicon and for thermoluminescent dosimeters such as calcium fluoride.
The container also changes the dose rate inside it, which is why the field intensity has to be measured inside the box, with the dosimeter at the device position, and remeasured whenever the source, the orientation, the container or the fixture changes. The requirement can be waived, but only by demonstrating that the low energy scattered component is small enough not to cause a dosimetry error. That is a measurement, not an assertion.
What this does not license. The container equalises the field around the package. It does not remove dose enhancement inside the die, where high atomic number metallization sits micrometers from the oxide. That is a device level effect and it is why a cobalt 60 result and an x-ray wafer probe result on the same part can differ.
Where it is written down
- MIL-STD-883, Method 1019, 3.4. Requires specimens to be enclosed in a lead and aluminum container to minimize dose enhancement from low energy scattered radiation; a minimum of 1.5 mm lead surrounding an inner shield of at least 0.7 mm aluminum; states the purpose is approximate charged particle equilibrium for silicon and for dosimeters such as calcium fluoride; requires the field to be measured inside the container initially and after any change of source, orientation, container or fixture; permits omission only on demonstration that scattered low energy radiation will not cause dosimetry error.
- MIL-STD-750, Method 1019, 3.4. Same requirement for discrete semiconductors, with the thicknesses given as 0.059 inch of lead and 0.028 inch of aluminum.
- ESCC Basic Specification No. 22900, 4.1.3. Same container requirement and the same stated purpose.
- MIL-STD-883, 2.2. References ASTM E1250 for assessing the low energy gamma component of cobalt 60 irradiators.
Why is the standard total dose rate 50 to 300 rad(Si) per second?50 to 300 rad(Si)/sThe lower bound is where enhanced low dose rate sensitivity starts. The upper bound is a practical limit that the documents state without justifying.
The 50 rad(Si)/s floor is not arbitrary and it is not about beam economics. MIL-STD-883 Method 1019 defines enhanced low dose rate sensitivity as enhanced damage below 50 rad(Si)/s, and requires bipolar and BiCMOS linear or mixed signal parts destined for applications below that rate to be handled under the low dose rate provisions. Condition A therefore sits exactly at the boundary of the regime where the standard test is known to be non-conservative for bipolar technology.
The 300 rad(Si)/s ceiling is stated in the same clause with no reason attached, in any of the documents reviewed here. It is best understood as the point beyond which the irradiation becomes short compared with the timescales of hole transport and interface trap formation, so that the test stops resembling any real exposure. Note that ESCC 22900 uses a different and much lower window, 1 to 10 rad(Si)/s for its standard rate, and justifies its choice on a completely different basis, namely that the exposure should finish inside 96 hours.
The practical consequence is that a part qualified to Condition A of Method 1019 and a part qualified to the ESCC standard rate have not had the same test, and for a bipolar part they may not have the same answer.
What this does not license. Nothing about the standard window makes it representative. A geostationary mission delivers its dose at the order of millirad per second, which is three to five orders of magnitude below Condition A.
Where it is written down
- MIL-STD-883, Method 1019, 3.6 and 3.6.1. Condition A dose rate is 50 to 300 rad(Si)/s. 3.6 requires bipolar and BiCMOS linear or mixed signal parts used below 50 rad(Si)/s to be handled under the low dose rate provisions unless shown not to exhibit an enhanced response.
- MIL-STD-883, Method 1019, 1.1. Defines enhanced low dose rate sensitivity as enhanced damage below 50 rad(Si)/s, which is what fixes the lower bound of the standard condition.
- ESCC Basic Specification No. 22900, 4.3. Uses 1 to 10 rad(Si)/s as its standard rate and 10 to 100 mrad(Si)/s as its low rate, and states the rate shall be adjusted so total exposure time stays under 96 hours.
Cited as the origin
- Derbenwick, G. and Sanders, H., 1977, CMOS Hardness Prediction for Low Dose Rate Environments. IEEE Transactions on Nuclear Science 24, 2244. Cited by MIL-HDBK-814 as origin of the rule that a dose specification must state the rate and the delivery time, not only the total
Why is the low dose rate condition 10 millirad(Si) per second, and why will an accelerated test plus an anneal not substitute?10 mrad(Si)/sBecause in bipolar oxides the damage is not simply a function of accumulated dose. Method 1019 says outright that the fast test plus anneal cannot simulate it.
In a thick, poor quality isolation oxide of the kind found in bipolar linear parts, the holes generated by irradiation move slowly and the space charge they build up affects how many of them are trapped and how many interface traps form. Deliver the same total dose quickly and the space charge shields part of the oxide; deliver it slowly and it does not. The result is that the slow exposure does more damage, which is the opposite of the intuition that a fast test is the conservative one.
Method 1019 does not hedge on this. It states that many bipolar linear parts exhibit an enhanced low dose rate response which cannot be simulated by a room temperature irradiation at 50 to 300 rad(Si)/s followed by an elevated temperature anneal. Condition D exists because of that, at 10 mrad(Si)/s or below, and the method requires that any alternative bounding approach be demonstrated with overtest or parameter delta margins rather than assumed. ASTM F1892 gives the same idea a name, defining a true dose rate effect as one that cannot be reproduced by a high rate irradiation and an equivalent anneal.
10 mrad(Si)/s is still roughly a thousand times faster than a geostationary mission. It is a bounding rate chosen so the test finishes, not a mission simulation, and even at that rate a full exposure takes weeks.
What this does not license. Passing at 10 mrad(Si)/s bounds the response at 10 mrad(Si)/s. Some parts continue to degrade as the rate falls further, and MIL-STD-750 has no equivalent of the Method 1019 enhanced response section at all, so a discrete qualified under 750 may never have been asked the question.
Where it is written down
- MIL-STD-883, Method 1019, 3.6.4. Condition D dose rate at or below 10 mrad(Si)/s.
- MIL-STD-883, Method 1019, 3.13 to 3.13.3. States that many bipolar linear parts exhibit an enhanced low dose rate response that cannot be simulated by a 50 to 300 rad(Si)/s irradiation plus elevated temperature anneal, and requires any bounding procedure to be demonstrated using overtest or parameter delta design margins.
- ASTM F1892, terminology. Defines a true dose rate effect as a response occurring during low dose rate irradiation that cannot be reproduced by a high dose rate irradiation followed by an equivalent time anneal.
- ESCC Basic Specification No. 22900, 4.3. Low rate window of 10 to 100 mrad(Si)/s, used when the preliminary evaluation identifies strong time dependent effects.
Cited as the origin
- Enlow, E. W., Pease, R. L., Combs, W., Schrimpf, R. D. and Nowlin, R. N., 1991, Response of advanced bipolar processes to ionizing radiation. IEEE Transactions on Nuclear Science 38(6), 1342. The paper that established the enhanced low dose rate response in bipolar technology
- Fleetwood, D. M., 1988, Physical mechanisms contributing to device rebound. IEEE Transactions on Nuclear Science 35(6), 1099
Why 100 degrees C for 168 hours after the irradiation?100 C for 168 hoursBecause the two kinds of trapped charge in an irradiated oxide anneal on different timescales, and the worst moment for the part is after the fast one has gone and the slow one has not.
Irradiation of a MOS oxide leaves two things behind: positive charge trapped in the oxide, and negative charge in interface traps at the silicon boundary. In an n-channel transistor they shift the threshold in opposite directions, so immediately after a fast irradiation they partly cancel. The trapped positive charge anneals relatively quickly. The interface traps do not, and can continue building. So a part measured an hour after the irradiation can look acceptable, and the same part weeks later can be out of specification. That is rebound, and ESCC 22900 defines it in those terms, as net degradation from changes in trapped oxide charge and interface state density over periods of the order of several weeks.
The accelerated aging step is built to reproduce that worst moment quickly. Method 1019 specifies 100 degrees C plus or minus 5 for 168 hours plus or minus 12, under worst case static bias, preceded by an additional half of the specified dose. The method also states the target directly in its alternative condition: more than 60 percent annealing of trapped holes and less than 10 percent annealing of interface states. The temperature and the duration are the values that hit that split, they are not round numbers chosen for convenience.
The mirror image of this procedure is the extended room temperature anneal, which uses the same physics in the other direction to recover a part that failed immediately after irradiation because of trapped positive charge that will not be there in flight.
What this does not license. The anneal step is a bounding construction with a stated split between the two mechanisms. It is not a mission simulation, and for a bipolar part with an enhanced low dose rate response it does not address the problem at all.
Where it is written down
- MIL-STD-883, Method 1019, 3.12.2. Specifies the additional half specified dose irradiation followed by 100 degrees C plus or minus 5 for 168 hours plus or minus 12 under worst case static bias, and states the target of greater than 60 percent trapped hole annealing with less than 10 percent interface state annealing.
- ESCC Basic Specification No. 22900, 3.1 and 5.4. Defines rebound as net degradation from changes in trapped oxide charge and interface state density over periods of the order of several weeks, and specifies the same 100 degrees C for 168 hours accelerated aging.
- MIL-HDBK-814, 4.1.3.1.1. Presents the classification of post-irradiation response curves into acceptable recovery, rebound and reverse anneal, and explains the competing mechanisms behind them.
Cited as the origin
- Boesch, H. E. Jr., 1986, A Proposed Schema for Measuring and Categorizing the Total Ionizing Radiation Dose Response of MOS Devices. IEEE Transactions on Nuclear Science 33, 1337. Cited by MIL-HDBK-814 as the origin of the rebound classification
- Winokur, P. S., Kerris, K. G. and Harper, L., 1983, Predicting CMOS inverter response in nuclear and space environments. IEEE Transactions on Nuclear Science 30(6), 4326
- Fleetwood, D. M., 1988, Physical mechanisms contributing to device rebound. IEEE Transactions on Nuclear Science 35(6), 1099
Why must the electrical measurement start within one hour of the irradiation?1 hour, 2 hoursBecause annealing starts the moment the beam stops, so the delay is part of the test condition whether it is controlled or not.
The quantity being measured is changing while it is being measured. Trapped charge begins to anneal at room temperature immediately, so a part measured at 20 minutes and the same part measured at 6 hours give different numbers, and neither is more correct than the other. Fixing the interval is what makes results comparable between laboratories and between lots.
MIL-STD-883 and MIL-STD-750 Method 1019 and ESCC 22900 all set the same limits: measurement to begin within 1 hour of the end of the exposure, and the next irradiation to begin within 2 hours, with longer intervals for the slower conditions and a dry ice option to suspend the annealing when the schedule cannot be met. All three say the same thing about why, that the intervals should be as short as practical to minimize time dependent effects.
This is one of the most commonly broken requirements in practice, and it breaks silently: nothing in the data shows that the part sat overnight, and the part that sat overnight looks harder.
What this does not license. Meeting the interval does not make the measurement time independent, it makes it consistently time dependent. Comparing your data with a report that does not state its interval is comparing two different quantities.
Where it is written down
- MIL-STD-883, Method 1019, 3.10. Maximum 1 hour to the start of electrical measurement and 2 hours to the next irradiation for Condition A, with scaled intervals for the other conditions, a dry ice option, and the stated purpose of minimizing time dependent effects.
- MIL-STD-750, Method 1019, 3.10. The same 1 hour and 2 hour limits for discrete semiconductors.
- ESCC Basic Specification No. 22900, 4.8. The same limits, requiring justification for anything longer.
Cited as the origin
- Pruitt, T. et al., 1978, A Technique to Measure Short Term Annealing in MOS Microprocessors. IEEE Transactions on Nuclear Science 25, 1205. Cited by MIL-HDBK-814 for the short term annealing measurement problem
Why 1.5 times the specification dose?1.5xOvertesting is a way of trading dose margin against sample size. The statistics behind that trade are worked out; the specific value of 1.5 is a convention.
If a lot is irradiated to a level above the requirement and passes, that is stronger evidence than a pass at the requirement, and it is stronger in a quantifiable way. MIL-HDBK-814 works the relation through for a lognormal failure distribution and shows that overtesting reduces the sample size needed to reach a given acceptance confidence. That is the actual justification for the practice, and it is a statistical one.
The particular factor of 1.5 appears in Method 1019 for the prescribed low dose rate path and in ASTM F1892's definition of an overtest factor, and in both cases it is asserted rather than derived from that relation. It is best treated as a convention that is known to be useful rather than as an optimum.
Radiation design margin is a different quantity and should not be confused with this one. Overtest is applied in the test to buy statistical strength on a given lot. Design margin is applied in the requirement to cover environment uncertainty and lot to lot variation.
What this does not license. Overtest works when the response distribution is well behaved and the failure mechanism does not change with level. Neither assumption holds for a part with a sharp functional failure or a second failure mode that only appears at high dose.
Where it is written down
- MIL-STD-883, Method 1019, 3.13.3. Requires a pass at 1.5 times the specification dose for the prescribed low dose rate acceptance path.
- ASTM F1892, terminology. Defines the overtest factor used in dose rate sensitivity acceptance.
- MIL-HDBK-814, 5.8.15. Derives the relation between overtest ratio, survival probability, confidence and sample size for a lognormal response distribution.
Cited as the origin
- Namenson, A., 1982, Hardness Assurance and Overtesting. IEEE Transactions on Nuclear Science 29, 1821. Cited by MIL-HDBK-814 as the origin of the overtest rule and its statistical formulation
Why is 100 mils of aluminum the default shielding assumption?100 mils of aluminumBecause it is roughly what a real spacecraft wall provides, and it can be assumed before the structure exists. It is a convention of convenience, and the documents say so.
Typical spacecraft shielding falls in the range of about 100 to 250 mils of aluminum equivalent, so 100 mils is a defensible lower end of the real range. The NASA avionics RHA guidelines describe the practice plainly: the environment is transported through an assumed nominal level of shielding, often 100 mils of aluminum equivalent, using an idealized slab or solid sphere geometry, and the analysis is refined toward real geometry once there is a model to refine it with.
What matters more than the number is what changes when you move it. Going from 100 to 250 mils cuts the trapped proton dose by less than a factor of two, and the electron contribution to dose is already negligible beyond about 100 mils. So within the range that spacecraft actually occupy, the shielding assumption is not a strong lever on total dose, and it is almost no lever at all on the cosmic ray heavy ion spectrum.
No document in this library derives 100 mils from an optimization. It is a starting point that has survived because it is approximately right and universally understood.
What this does not license. A 100 mil result is a slab calculation. Real spacecraft have boxes inside boxes and instruments on booms, and the actual shielding distribution seen by a given part can be several times thinner or thicker in some directions.
Where it is written down
- NASA/TM-20210018053, environment definition section. States that baseline requirements transport trapped particles and solar protons through an assumed nominal shielding level, often 100 mils of aluminum equivalent, using an idealized slab or sphere, refined later toward realistic geometry.
- Schwank, Shaneyfelt and Dodd, radiation environments and hardness assurance foundations. States typical spacecraft shielding is in the range of 100 to 250 mils, that going from 100 to 250 mils decreases proton dose by less than a factor of two, and that beyond about 100 mils the electron contribution to dose is negligible.
Cited as the origin
- Heinrich, W., 1977, Calculation of LET-Spectra of Heavy Cosmic Ray Nuclei at Various Absorber Depths. Radiation Effects 34, 143
- Adams, J. H. Jr., 1982, The Natural Radiation Environment inside a Spacecraft. IEEE Transactions on Nuclear Science 29(6), 2095
Why not just shield with lead, and what is graded Z actually for?lead versus aluminumBecause stopping an electron in a high atomic number material converts it into penetrating x-rays. Lead is a good photon absorber and a bad electron absorber, and the order of the layers matters.
When an energetic electron decelerates in matter it emits bremsstrahlung. The TREE handbook gives the scaling directly: the intensity depends linearly on the atomic number of the material and on the square of the initial electron energy, and the mean photon energy is about a third of the electron energy. So a lead first surface facing a trapped electron belt turns a stoppable particle flux into a photon flux that is much harder to stop. Aluminum is a poorer absorber per unit thickness but it produces far less bremsstrahlung, which is why spacecraft are built out of it.
The handbook also gives the quantitative picture for a low earth orbit: trapped electrons are almost entirely stopped by more than about 0.2 g/cm2 of aluminum, while the bremsstrahlung above 70 keV is essentially unaffected by aluminum anywhere from 0.1 to 10 g/cm2. The saving grace is that the photon fluxes above 100 keV are on average more than three orders of magnitude below the incident electron fluxes at the same energy.
That is the argument for grading the atomic number rather than picking one: a low atomic number outer layer to slow and stop the electrons while generating as little bremsstrahlung as possible, then a higher atomic number inner layer to absorb the photons that were generated anyway, and sometimes a final low atomic number layer to catch the secondary electrons the high atomic number layer produces. It should be said that the avionics RHA guidelines cite the graded material literature without spelling out this mechanism in their own text, so the reasoning above is assembled from the bremsstrahlung physics in the TREE handbook rather than quoted from a requirement.
Spot shielding is the same idea applied locally. Schwank and co-authors note that adding high atomic number layers around individual components can further shield a critical circuit, and that this is worthwhile against electrons but much less so in a proton rich orbit, where going from 100 to 250 mils buys under a factor of two.
What this does not license. Adding mass helps against electrons and the soft end of the solar proton spectrum. Against galactic cosmic rays it does essentially nothing, and in a heavy shield the nuclear secondaries produced in the shield itself begin to matter.
Where it is written down
- Transient Radiation Effects on Electronics Handbook, DNA-H-95-61, 1.4.1.6. States that bremsstrahlung intensity depends linearly on atomic number and on the square of the electron energy, that mean photon energy is about a third of the electron energy, that low atomic number spacecraft materials produce less bremsstrahlung, and gives the aluminum attenuation figures for electrons and for the resulting photons in a 500 km orbit.
- Schwank, Shaneyfelt and Dodd, radiation environments and hardness assurance foundations. States that shielding creates secondaries including bremsstrahlung, that spot shielding with high atomic number layers can further protect critical circuits, that the electron contribution to dose becomes negligible beyond about 100 mils, and that spot shielding is less effective in proton rich environments.
- NASA/TM-20210018053, reference list. Cites the graded atomic number shielding literature, specifically Atwell, Rojdev, Aghara and Sriprisan, AIAA 2013-5385, without developing the mechanism in the body text.
Cited as the origin
- Atwell, W., Rojdev, K., Aghara, S. and Sriprisan, S., 2013, Mitigating the Effects of the Space Radiation Environment, A Novel Approach of Using Graded-Z Materials. AIAA 2013-5385
Why does more shielding barely help against cosmic rays when it works so well against solar protons?6.5 inches for 10xBecause solar particles are soft enough to range out in practical thicknesses and galactic cosmic rays are not.
The two populations sit at different places on the energy axis. A large solar particle event is dominated by particles of modest energy, so bulk material genuinely removes them: Schwank and co-authors report that going from 25 mils to about 1570 mils of aluminum cuts the flare flux above LET 30 by five orders of magnitude. Over the same span, the galactic cosmic ray LET spectrum is barely touched, because those particles carry hundreds of MeV to many GeV per nucleon.
The consequence for single event rates was put into a memorable form by Petersen and repeated in the CREME96 literature: error rates fall by roughly a factor of ten behind about 6.5 inches of aluminum. Since a spacecraft wall is a tenth of an inch, shielding is not a single event mitigation. It is a total dose mitigation, and a good one, in orbits where dose comes from trapped particles.
This is the structural reason single event work is organized the way it is. Total dose can be engineered against with mass; single events cannot, so they are engineered against with part selection, derating, detection and recovery.
What this does not license. Shielding still matters for the soft solar spectrum, which is what drives the worst hours of an event. A single event budget that ignores solar particle enhancement because cosmic rays cannot be shielded has confused the two populations.
Where it is written down
- Schwank, Shaneyfelt and Dodd, radiation environments and hardness assurance foundations. Compares flare and cosmic ray LET spectra against aluminum thickness, reporting a five order of magnitude reduction in flare flux above LET 30 between 0.17 and 10.8 g/cm2, and only a slight effect on the cosmic ray spectrum out to 10 g/cm2.
- CREME96 and related error rate prediction methods. Quotes the rule of thumb, attributed to Petersen, that error rates fall by about a factor of ten behind 6.5 inches of aluminum.
- Transient Radiation Effects on Electronics Handbook, DNA-H-95-61. States that aluminum shielding is effective for low energy protons and ineffective above about 30 MeV, and that shielding against high energy cosmic rays is impractical.
Cited as the origin
- Adams, J. H. Jr., 1983, The variability of single event upset rates in the natural environment. IEEE Transactions on Nuclear Science 30(6), 4475
- Tylka, A. J. et al., 1997, CREME96, A Revision of the Cosmic Ray Effects on MicroElectronics Code. IEEE Transactions on Nuclear Science 44(6), 2150
Why are solar particle environments quoted as a worst week, a worst day and a peak 5 minutes?worst week, worst day, peak 5 minutesBecause they are three different engineering questions, and CREME96 built all three from the same event, October 1989, at about the 99 percent confidence level.
The three models in CREME96 are constructed from measured data during the October 1989 event: about 180 hours of it for the worst week, an 18 hour interval for the worst day, and the highest 5 minute average proton flux for the peak, with heavy ion fluxes scaled from the proton data. All three are described as worst case at roughly the 99 percent confidence level.
The integration times exist because different failure modes integrate over different windows. Accumulated dose and total upset count over an event care about the week. A single event rate that has to stay inside a fault management budget cares about the peak, because that is when a detection and recovery scheme is most likely to be overwhelmed by coincident events. The documents present the three products for these different uses without deriving the specific windows, so the mapping between window and failure mode is engineering practice rather than a stated requirement.
Note the change from the earlier code: CREME86 used a 10 percent worst case flux, meaning only one in ten events would be more severe, which is a different kind of statement from a confidence level on a fluence.
What this does not license. These are worst case models built from one very large event. They are not a probability distribution over mission life, and a mission that needs a fluence at a stated confidence over a stated duration needs a statistical solar proton model instead.
Where it is written down
- CREME96 and related error rate prediction methods. Describes the worst week, worst day and peak 5 minute models built from October 1989 data, states they are worst case at about the 99 percent confidence level, and contrasts them with the 10 percent worst case convention used in CREME86.
Cited as the origin
- Tylka, A. J. et al., 1997, CREME96, A Revision of the Cosmic Ray Effects on MicroElectronics Code. IEEE Transactions on Nuclear Science 44(6), 2150
- Tylka, A. J., 2005, Shock Geometry, Seed Populations, and the Origin of Variable Elemental Composition at High Energies in Large Gradual Solar Particle Events. Astrophysical Journal 625, 474
Why is the sensitive volume modeled as a rectangular box, and why a Weibull?rectangular parallelepipedBecause a box is the shape whose chord length distribution has a closed form, and the Weibull is a curve that fits. Neither is a physical claim, and the literature is explicit about that.
The rate integral needs the distribution of path lengths through the sensitive volume, because deposited charge is LET times chord length. A rectangular parallelepiped is used because Bradford derived a closed form chord length distribution for it, which makes the integral tractable. That is the entire reason for the shape.
The Weibull has even less claim to physical meaning. It is a four parameter curve with the right qualitative behavior, a threshold and a saturation, and it fits. Edmonds says this bluntly in his review of CREME96 practice: the Weibull function has no physical basis, and a two parameter exponential often fits as well.
This matters because the parameters get over-interpreted. The same review warns that the box thickness must be chosen so the model reproduces the measured angular dependence, not set equal to a physical charge collection or funnel depth, and reports that using a literal collection depth of tens of microns instead of the sub-2 micron value that reproduces the directional response can inflate a rate estimate by two orders of magnitude. The funnel is real physics; putting it into the box thickness by hand is not how the model works.
What this does not license. The model is a fitting device that turns measured cross section into predicted rate. It is not valid for destructive effects, and its parameters are not device dimensions.
Where it is written down
- CREME96 and related error rate prediction methods. Describes the rectangular parallelepiped model and its chord length distribution, the integral form, the field funnelling correction, and the four stated limiting assumptions of the basic model, together with the integral form that relaxes the step threshold assumption.
- Recommendations regarding the use of CREME96 for heavy ion upset rate calculations, JPL, 2005. States that the model is rarely a literal description of charge collection physics, that box dimensions must be chosen to reproduce the directional cross section, and quantifies the error from using a literal collection depth.
- NASA/TM-20210018053, archival data and rate calculation sections. States that the rectangular parallelepiped method is not valid for all effect types, and names dielectric rupture, gate rupture and burnout as exceptions.
Cited as the origin
- Pickel, J. C. and Blandford, J. T. Jr., 1978, Cosmic Ray Induced Errors in MOS Memory Cells. IEEE Transactions on Nuclear Science 25(6), 1166
- Bradford, J. N., 1979, A distribution function for ion track lengths in rectangular volumes. Journal of Applied Physics 50(6), 3799
- Hsieh, C. M., Murley, P. C. and O'Brien, R. R., 1981, A field-funneling effect on the collection of alpha-particle-generated carriers in silicon devices. IEEE Electron Device Letters 2, 103
- Edmonds, L. D., 1996, SEU Cross Sections Derived from a Diffusion Analysis. IEEE Transactions on Nuclear Science 43(6), 3207
How accurate is a single event rate prediction, and why is it not better?factor of 2 to 5A good prediction agrees with the observed on-orbit rate within a factor of two to five. The residual comes from four sources and only one of them is fixable by more testing.
The NASA avionics RHA guidelines state the expectation directly: a good rate estimate should agree with the observed on-orbit rate within a factor of two to five, citing Petersen's short course and the data workshop literature. They also list where the error comes from: the environment model, part to part variation, departures from the assumed sensitive volume geometry, and Poisson counting error on the cross section measurements. Only the last of those gets better by running more beam time.
This is a useful number to hold onto in both directions. A prediction that misses flight data by a factor of three is behaving as documented. A prediction quoted to two significant figures is claiming a precision the method does not have, and an argument that turns on a factor of two difference between two predictions is not an argument.
There is a separate and much larger error mode which is not part of this figure, namely using the model wrongly. The CREME96 usage review shows that choosing a physically motivated but incorrect sensitive volume thickness can move a rate estimate by two orders of magnitude, which dwarfs everything above.
For the historical record, the first cosmic ray upset rate calculation, by Binder, Smith and Holman in 1975, landed within a factor of two of the observed satellite anomalies. The state of the art has not improved on that by very much, and for structural reasons it is not likely to.
What this does not license. The factor of two to five applies to upset in parts that fit the model. It does not carry over to destructive effects: burnout and rupture depend on bias and on ion energy and range in ways an LET only framework does not carry, so the usual answer is a derating to a safe operating voltage, and any rate quoted for them is a bound with a stated, and large, uncertainty.
Where it is written down
- NASA/TM-20210018053, rate estimation section. States a good rate estimate should agree within a factor of two to five with the observed on-orbit rate, and lists environment model uncertainty, part to part variation, deviation from the assumed geometry, and Poisson counting error as the contributors.
- Recommendations regarding the use of CREME96 for heavy ion upset rate calculations, JPL, 2005. Documents a case where inappropriate sensitive volume thickness inflated a rate estimate by two orders of magnitude.
- Transient Radiation Effects on Electronics Handbook, DNA-H-95-61. Notes that the first cosmic ray upset rate calculation agreed with observed anomalies within a factor of two.
Cited as the origin
- Binder, D., Smith, E. C. and Holman, A. B., 1975, Satellite Anomalies from Galactic Cosmic Rays. IEEE Transactions on Nuclear Science 22(6), 2675
- Petersen, E. L., 2008, Soft Error Results Analysis and Error Rate Prediction. IEEE NSREC Short Course
- Petersen, E. L., Pickel, J. C., Adams, J. H. Jr. and Smith, E. C., 1992, Rate Prediction for Single Event Effects, a Critique. IEEE Transactions on Nuclear Science 39(6), 1577
Why is the derating 75 percent in one document and 25 percent in another?75 percent, 50 percent, 25 percentBecause they are derating from different things. 75 percent is of a measured failure voltage. 25 percent is of a manufacturer's rating on a part nobody has tested.
The JPL gate rupture guideline derates from the test result. Its worked example takes a device rated 100 V that ruptures at 80 V under beam, and arrives at 60 V for use, which is 75 percent of the measured threshold and 60 percent of the nameplate. The NASA avionics RHA guidelines do the same thing, deriving an operating limit of 58.5 V from a 78 V measured survival voltage. In this construction the 75 percent covers part to part variation and test uncertainty around a number that was actually measured on that part type.
Derating from the datasheet is a different procedure. For a commercial part there is usually no test result, so the factor has to cover the spread of commercial device response as well as the margin, and the factors in use are correspondingly harsher and vary by technology. Confusing the two is a common and expensive error. Applying 75 percent to a datasheet rating on an untested commercial part is not the same procedure as applying 75 percent to a measured rupture voltage, and it does not carry the same evidence.
One further complication is that a nameplate rating is not always what it appears. A supplier selling into the space market may already have applied its own margin before publishing a rating, in which case a derating factor applied on top is being applied twice, invisibly, and the design gives up voltage it did not need to. There is nothing in the documents reviewed here that addresses this, and the only defense is to derate from a measured failure voltage with a known test protocol rather than from a rating.
What this does not license. A derating percentage is only as meaningful as the voltage it is applied to. Always record whether the base is a measured failure voltage, a measured survival voltage, or a datasheet rating, because those three differ by more than the derating factor does.
Where it is written down
- JPL Publication 08-10, general derating section. Gives a derating factor of 0.75 on tested threshold voltage, notes that 75, 50 and 25 percent are all in common use, and works an example from a measured rupture voltage.
- NASA/TM-20210018053, single event burnout and gate rupture sections and Appendix B. States that voltage derating is effective mitigation, gives a worked example deriving an operating limit from a measured survival voltage, and gives example specification language requiring derating to 75 percent of the maximum survivable voltage.
- Pulsed-Laser Single-Event Effects Testing, DTRA-TR-23-43. Reports a case where the common 50 percent rule of thumb was non-conservative, with a 500 V rated part showing a safe operating boundary near 90 to 100 V.
Cited as the origin
- George, J. S. et al., 2017, Response Variability in Commercial MOSFET SEE Qualification. IEEE Transactions on Nuclear Science 64(1), 317
- Titus, J. L., 2013, An Updated Perspective of Single Event Gate Rupture and Single Event Burnout in Power MOSFETs. IEEE Transactions on Nuclear Science 60(3), 1912
- Luu, A. et al., 2008, SEB Characterization of Commercial Power MOSFETs With Backside Laser and Heavy Ions of Different Ranges. IEEE Transactions on Nuclear Science 55(4), 2166
Why are design margins of 2, 10 and 100 the breakpoints for part categorization?2x, 10x, 100xThey are historical engineering conventions that set how much ongoing lot control a part needs, not statistical thresholds.
The design margin breakpoint method sorts parts by the ratio of the level at which they fail to the level the mission requires. Below about 2 the part is unacceptable. Between 2 and 10 it is hardness critical in the strict sense and every purchased lot has to be tested. Between 10 and 100 it is hardness critical in a weaker sense and occasional confirmatory testing suffices. Above 100 it is hardness non-critical and can be bought like any other part.
The logic is about variability rather than about the mean. A large margin means that even a lot several times worse than the one tested still passes, so the consequences of not testing every lot are small. A margin of 2 means an ordinary lot to lot excursion can put the part over the line, so every lot must be checked. The TREE handbook, which sets out the method, describes the specific breakpoints as conventions used by the services rather than as a derived criterion, and offers an alternative that ties the breakpoint to each part's measured response variability instead.
MIL-HDBK-814 gives the underlying statistical point for the low end: a part with a margin of one has about a 50 percent chance of surviving, which is why a margin near unity is not a margin at all. It recommends a minimum of 2 to 3 while acknowledging that at very high dose levels a factor of 3 may not be achievable.
The NASA avionics RHA guidelines are notably more skeptical, describing the margin approach as ad hoc, capable of both under and over specifying, and note that the agency is moving toward quantifiable assurance methods. They do not prescribe a fixed factor.
What this does not license. Design margin categorization assumes the failure distribution is well behaved. For a part with a bimodal response, a comfortable margin computed against the main mode says nothing about the second one.
Where it is written down
- Transient Radiation Effects on Electronics Handbook, DNA-H-95-61, design margin breakpoint sections. Sets the breakpoints at 2, 10 and 100 with the corresponding categorization and lot control implications, describes them as service conventions rather than derived thresholds, and offers a variability based alternative.
- MIL-HDBK-814, 5.1.9. Recommends a minimum design margin of 2 to 3, notes that a margin of one implies about 50 percent survival probability, and allows practical relief at very high dose levels.
- NASA/TM-20210018053, design margin section. Defines radiation design margin as failure level over specification level, describes the approach as ad hoc and capable of under or over specifying, and does not prescribe a numeric target.
Cited as the origin
- Namenson, A. and Arimura, I., 1985, Estimating Electronic Parameter End-points for Devices Which Suffer Abrupt Functional Failure During Radiation Testing. IEEE Transactions on Nuclear Science 32, 4250
- Arimura, I. and Namenson, A., 1983, Hardness Assurance Statistical Methodology for Semiconductor Devices. IEEE Transactions on Nuclear Science 30, 4322
Why are protons tested at about 200 MeV, and why is 63 MeV the other common point?200 MeV, 63 MeV200 MeV is where the indirect ionization cross section has saturated and the dose per proton is lowest. 63 MeV is roughly the median of the trapped spectrum and is what many cyclotrons deliver.
Above roughly 100 MeV the proton upset cross section of most parts has stopped changing, because the nuclear reaction cross sections that produce the ionizing recoils have leveled off. A single point above that captures the saturated value, and JESD234 states that testing above 200 MeV is not generally necessary for non-destructive upset because higher energy protons are rare enough in the environment that the extra contribution to the rate is small.
The dose argument points the same way and is worth doing explicitly. A 30 MeV proton deposits about 3.0e-7 rad(Si) per proton per square centimeter, a 63 MeV proton about 1.8e-7, and a 200 MeV proton about 7.0e-8. So the fluence needed for good statistics costs about 30 krad at 30 MeV, 18 krad at 63 MeV and 7 krad at 200 MeV. This is why Schwank and co-authors recommend starting at high energy: it minimizes the dose accumulated before the measurement is made, and if the cross section turns out to be flat the low energy points can be skipped entirely.
63 to 65 MeV is common for a different reason: it is what a large number of cyclotrons produce, and the older guidance notes that in the trapped environment there are roughly as many protons below 60 MeV as above, so a single point near there is representative if only one can be afforded. Its weakness is stated just as plainly, that a facility limited to 63 MeV may be too low to reach saturation.
For latchup the logic reverses and the highest available energy is the right choice. Schwank and co-authors go further and advise against proton latchup testing at facilities below 180 MeV at all, because latchup probability can be significantly underestimated, and JESD234 notes devices where latchup was seen only above 400 MeV, driven by spallation reactions in high atomic number metallization.
What this does not license. A saturated cross section at 200 MeV does not give the threshold, and the threshold is what matters in a soft trapped spectrum. Two energies are the minimum for a two parameter fit, and one energy fixes only the plateau.
Where it is written down
- JESD234, 1 and 3.6. Scopes the standard to 40 to 500 MeV on the grounds that indirect ionization dominates there and that the range matches available facilities, and states that testing above 200 MeV is not considered necessary for non-destructive upset because high energy protons are relatively rare, while destructive screening may require the full range.
- NASA proton single event effects guidance, August 2009. Recommends a three point energy curve at 60, 120 and 190 MeV plus or minus 10 MeV to bound the sensitivity curve, and permits waiving further points when sensitivity is low at all three.
- Proton test guideline development, lessons learned, 2002. States that most cross section curves are saturated above 100 MeV, recommends 60 MeV where only one energy is possible because the trapped spectrum is roughly evenly divided there, notes that 63 MeV facilities may be too low to reach saturation, and recommends the highest available energy for latchup screening.
- Schwank, Shaneyfelt and Dodd, proton and heavy ion test guideline. Requires a source spanning at least 20 to 180 MeV, recommends starting at high energy to minimize accumulated dose, and advises against proton latchup testing at facilities below 180 MeV.
Cited as the origin
- Bendel, W. L. and Petersen, E. L., 1983, Proton Upsets in Orbit. IEEE Transactions on Nuclear Science 30(6), 4481
- Stapor, W. J., Meyers, J. P., Langworthy, J. B. and Petersen, E. L., 1990, Two Parameter Bendel Model Calculations for Predicting Proton Induced Upset. IEEE Transactions on Nuclear Science 37(6), 1966
- Schwank, J. R. et al., 2005, Effects of particle energy on proton-induced single-event latchup. IEEE Transactions on Nuclear Science 52(6), 2622
Why is the proton fluence 1e10 or 1e11 per square centimeter, and why does the part sometimes die first?1e10 to 1e11 protons/cm2Because that is the fluence needed to bound a small cross section, and at low proton energy it is also enough dose to destroy the part.
The statistics are the same as for heavy ions: with no events, the bound on the cross section is a constant over the fluence. JESD234 gives a nominal 1e10 protons/cm2 for soft devices and 1e12 for hard ones, with a rule of thumb of a hundred events where events are available. The 2002 lessons learned guidance is more specific about the null case: stop either at 1e11 protons/cm2 or when the part is destroyed, whichever comes first.
That phrase, whichever comes first, is the whole problem. At 30 MeV, 1e11 protons/cm2 deposits about 30 krad(Si), which is above the total dose capability of a great many commercial parts. So for a hard part the single event test and the total dose test are the same test whether you intended that or not, and the cross section you measure at the end of the run is the cross section of a degraded device.
This is why the standards insist on tracking dose during the run and swapping parts. JESD234 suggests replacing devices at 20 to 50 percent of the established total dose or displacement damage failure level; the NASA proton guidance uses 80 percent of known tolerance. Those two numbers disagree, and the disagreement is worth knowing about when reading somebody else's report.
What this does not license. A proton null result at 1e11 bounds the proton cross section. It does not bound the heavy ion response, and the widespread practice of treating a clean proton run as evidence of general single event hardness is not supported by any of these documents.
Where it is written down
- JESD234, 5.8 and 7.9.4.1. Gives a nominal 1e10 protons/cm2 for soft devices and 1e12 for hard devices, a hundred event rule of thumb, and a stopping criterion at 1e10 or the event target whichever comes first, balanced against total dose capability.
- Proton test guideline development, lessons learned, 2002. Requires about a hundred events for ten percent counting error, and directs that a null test stop at 1e11 protons/cm2 or on destruction of the part. Gives 3e-7 rad(Si) per 30 MeV proton per square centimeter as the dose conversion.
- JESD234, 3.6 and 7.1.4. States that total dose and displacement damage accumulate during any proton run and can shift the cross section, and recommends replacing parts at 20 to 50 percent of the established failure limit.
- NASA proton single event effects guidance, August 2009. Recommends that dose accumulated during single event testing not exceed 80 percent of the device tolerance.
Cited as the origin
- Marshall, P. W. and Marshall, C. J., 1999, Proton Effects and Test Issues for Satellite Designers. IEEE NSREC Short Course, Norfolk
- Summers, G. P., 1992, Displacement Damage, Mechanisms and Measurements. IEEE NSREC Short Course, New Orleans
Why did low energy protons suddenly start mattering?below 2 to 5 MeVBecause critical charge fell far enough that a proton can upset a cell by direct ionization, without any nuclear reaction at all. That threshold was crossed at around the 65 nm node.
For most of the history of the field, protons upset parts indirectly: a nuclear reaction produced a recoil, and the recoil did the ionizing. A proton's own stopping power was simply too low to deposit the critical charge. As feature sizes shrank the critical charge fell, and at 65 nm and below the direct ionization from a slow proton near its Bragg peak became sufficient on its own.
The consequence is that the cross section stops being flat at low energy and instead rises steeply as energy falls, which is exactly the region the standard test methods exclude. JESD234 addresses this by prohibiting the case: it notes that direct ionization effects have been observed in technologies below 100 nm, primarily below 5 MeV, and states that testing at those energies is outside its scope. It also notes the effect extends to higher energies at glancing incidence, where the path length through the sensitive volume is longer.
Schwank and co-authors explain why no standard method exists yet, and the reasons are all practical. Putting the Bragg peak inside the sensitive volume with a genuinely low energy beam means large uncertainty by the time the proton has crossed the overlayers. Using a heavier ion at matched stopping power reduces straggle but needs careful energy loss modeling. Degrading a 60 to 70 MeV beam through added material adds straggle, but has the merit of resembling how low energy protons actually arise inside a spacecraft, as degraded higher energy protons.
What this does not license. This is a scaling effect, so it appears in new technology and not in old. A heritage part qualified under the older methods was not wrong at the time, but a modern part qualified the same way may have an unmeasured sensitivity at low energy.
Where it is written down
- JESD234, 3.4 and 3.6. States that direct ionization effects have been observed in technologies below 100 nm primarily below 5 MeV, prohibits testing at those energies as outside its scope, and notes the effect at glancing incidence extends to higher energies.
- NASA proton single event effects guidance, August 2009. Describes low energy proton testing as relevant only to technologies with very low critical charge, demonstrated on CMOS below 90 nm.
- Schwank, Shaneyfelt and Dodd, proton and heavy ion test guideline. States that direct ionization can greatly increase the cross section below about 2 MeV, and sets out the three practical approaches and their respective drawbacks.
Cited as the origin
- Rodbell, K. P. et al., 2007, Low-energy proton-induced single-event-upsets in 65 nm node, silicon-on-insulator, latches and memory cells. IEEE Transactions on Nuclear Science 54(6), 2474
- Heidel, D. F. et al., 2008, Low energy proton single-event-upset test results on 65 nm SOI SRAM. IEEE Transactions on Nuclear Science 55(6), 3394
- Sierawski, B. D. et al., 2009, Impact of low-energy proton induced upsets on test methods and rate predictions. IEEE Transactions on Nuclear Science 56(6), 3085
- Schwank, J. R. et al., 2012, Hardness assurance testing for proton direct ionization effects. IEEE Transactions on Nuclear Science 59(4), 1197
Why is latchup tested hot and burnout tested cold?hot for latchup, cold for burnoutBecause the two mechanisms depend on temperature in opposite directions, so the worst case for one is the benign case for the other.
Latchup is a parasitic thyristor turning on and holding itself on. Higher temperature raises the well and substrate resistances and raises the current gains of the parasitic bipolar transistors, both of which make the structure easier to trigger and easier to sustain. ASTM F1192 states the effect directly, that latchup susceptibility and soft error cross sections increase with temperature, and JESD57A and ESCC 25100 both require latchup testing at maximum rated operating voltage and maximum operating temperature.
Burnout is second breakdown in a parasitic bipolar structure in a power device, and it goes the other way. MIL-STD-750 Method 1080 states that higher temperature raises the burnout LET threshold, so lower operating temperature is the worst case. JESD57A gives the same guidance in its worst case table: burnout at maximum reverse bias and minimum operating case temperature. Gate rupture is treated as essentially temperature independent, and the JPL guideline says so explicitly.
Note that none of these documents give an absolute temperature. The requirement is always relative to the device's own rated maximum or minimum, which is why a test report that says 125 degrees C without saying what the part is rated to has not established that it tested the worst case.
One caution from the source text: MIL-STD-750 Method 1080 contains two notes that disagree with each other on the direction of the temperature effect, and only the later one is consistent with the rest of the literature. If you are working from that method, use the physics rather than the note.
What this does not license. A part screened hot for latchup and never screened cold has an untested burnout condition, and the reverse. For a mixed technology part such as a smart power device or a gate driver with CMOS control logic, both conditions apply and neither one covers the other.
Where it is written down
- ASTM F1192-11(2018), 6.4. States that latchup susceptibility and soft error cross sections increase with temperature.
- JESD57A, 5.2.5.3 and Annex A.12. Gives worst case conditions by effect type: latchup at maximum operating voltage and maximum operating case temperature, burnout at maximum reverse bias voltage and minimum operating case temperature, and gate rupture with temperature not a primary factor.
- ESCC Basic Specification No. 25100, 4.2.6. Latchup at maximum operating voltage and maximum operating temperature; burnout and gate rupture at low operating temperature, with room temperature usually acceptable.
- MIL-STD-750, Method 1080. States that higher temperature raises the burnout LET threshold and improves the gate rupture failure threshold voltage, so lower operating temperature is the worst case. Note that an earlier note in the same method contradicts this.
- JPL Publication 08-10, thermal stability section. States that gate rupture is not affected by temperature and that burnout likelihood decreases with increasing temperature, so burnout testing must be at a controlled temperature.
Cited as the origin
- Johnson, G. H., Schrimpf, R. D., Galloway, K. F. and Koga, R., 1992, Temperature dependence of single-event burnout in n-channel power MOSFETs. IEEE Transactions on Nuclear Science 39, 1605
- Mouret, I., Allenspach, M., Schrimpf, R. D., Brews, J. R. and Galloway, K. F., 1994, Temperature and angular dependence of substrate response in SEGR. IEEE Transactions on Nuclear Science 41, 2216
Why does it matter whether a destructive event was latchup or burnout?latchup mistaken for burnoutBecause they call for different mitigations, and because a dataset that lumps them together will give the wrong derating curve.
Both present the same way on the bench: current goes up sharply. What distinguishes them is what happens next. Latchup is a self-sustaining state that clears when power is removed, and it becomes destructive only if the current is allowed to run. Burnout in a power device is thermal destruction and does not clear. The JPL gate rupture guideline addresses this directly and says that a high current condition that recovers on power cycling should be noted but not recorded as burnout or gate rupture.
The consequence for data analysis is larger than it looks. Latchup depends on the current limit of the test fixture, on temperature in the opposite direction from burnout, and on the bias of the control logic rather than the power stage. A dataset that records recoverable latchup events as burnout failures will show failures at voltages far below the true burnout locus, and any derating fitted through those points will be unnecessarily severe. When reviewing a screen from any source, the first question about a destructive event should be whether the part recovered.
What this does not license. Recovery on power cycling separates latchup from burnout. It does not prove the part is undamaged, because latent damage from a high current event is real and shows up as a leakage shift rather than a functional failure.
Where it is written down
- JPL Publication 08-10, verification section. States that a recoverable high current condition is related to latchup in CMOS devices and that if the device recovers and operates normally the event should be noted but not recorded as gate rupture or burnout, while still being treated as a mission threatening effect pending further testing.
- NASA/TM-20210018053, single event types and archival data sections. Separates latchup, gate rupture, burnout and dielectric rupture by technology, and lists misattribution of effect type as a known risk when using archival data.
Cited as the origin
- Sexton, F. W., 2003, Destructive single-event effects in semiconductor devices and integrated circuits. IEEE Transactions on Nuclear Science 50(3), 603
- Johnston, A. H., 1996, The influence of VLSI technology evolution on radiation-induced latchup in space systems. IEEE Transactions on Nuclear Science 43(2), 505
Why can a pulsed laser not replace heavy ion testing?pulsed laserBecause it deposits charge by a different process with no intrinsic LET equivalence, and because light does not go through metal.
A focused laser pulse creates carriers by photon absorption, not by the coulomb interaction of a charged particle track. The spatial profile of the deposited charge is different, so there is no first principles conversion between pulse energy and LET. The desk reference is explicit that either an empirical correlation factor, which itself requires heavy ion data, or a tuned laser equivalent LET must be used, and that in most cases heavy ion and proton data are still required for a rate prediction.
The access problem is the other half. Laser light cannot pass through metal, so the interconnect stack, the package and opaque coatings all block the beam, which forces delidding, backside polishing to a mirror finish, or substrate thinning. The through-wafer route uses two photon absorption, which needs sub-bandgap photons, typically 1250 to 1550 nm in silicon rather than the 1064 nm used for single photon work, and the choice between them is dictated by the packaging rather than by preference.
There is also a geometry limitation: laser testing is done almost exclusively at normal incidence, because the working distance of the objective and refraction at the semiconductor surface make angled illumination impractical. That rules out the grazing angle work sometimes needed for hardened-by-design circuits.
What the laser is good at is the thing broad beam cannot do at all, which is telling you where on the die the sensitivity is. The two techniques answer different questions, which is why the literature calls them complementary rather than alternative.
What this does not license. Laser results are excellent for localization, sensitivity mapping and design feedback, and for comparing two design variants. They do not produce a cross section against LET curve that can be integrated against an environment.
Where it is written down
- Pulsed-Laser Single-Event Effects Testing, DTRA-TR-23-43, advantages and limitations sections. Frames the technique as complementary to broad beam testing, and states the limitations: opaque materials block the beam, there is no intrinsic conversion between pulse energy and LET, two photon absorption requires sub-bandgap wavelengths, and testing is almost exclusively at normal incidence.
- NASA/TM-20210018053, test technique comparison. States that broad beam heavy ion testing determines the LET that causes an effect but not the feature responsible, while laser testing identifies the vulnerable feature but yields only qualitative or limited quantitative information about the charge required.
Cited as the origin
- Ladbury, R. L., Benedetto, J., McMorrow, D., Buchner, S. P., LaBel, K. A., Berg, M. D., Kim, H. S., Sanders, A. B., Friendlich, M. R. and Phan, A., 2009, TPA Laser and Heavy-Ion SEE Testing, Complementary Techniques for SDRAM Single-Event Evaluation. IEEE Transactions on Nuclear Science 56(6), 3334
- Luu, A. et al., 2008, SEB Characterization of Commercial Power MOSFETs With Backside Laser and Heavy Ions of Different Ranges. IEEE Transactions on Nuclear Science 55(4), 2166
Why does a radiation result on one lot not transfer to another lot of the same part number?lot traceabilityBecause radiation response depends on process details that are not part of the electrical specification, and manufacturers change them without telling anyone.
Total dose response in particular depends on oxide growth conditions, hydrogen content and thermal history, none of which appear on a datasheet and none of which the manufacturer is obliged to hold constant. A part can meet every electrical parameter across a process change and behave completely differently under irradiation. The NASA avionics RHA guidelines state that design mask or fabrication process changes can invalidate archival data while form, fit and function are maintained, and that manufacturers are not necessarily required to give notice.
The guidelines put a timescale on it for leading edge commercial parts: die revisions can occur as often as every 18 months for state of the art memory. They also give the practical rule for archival data, that data on a non-flight lot usually has limited predictive value, and recommend more than three lots of historical data before drawing conclusions about variability.
The same guidelines make a related point that is easy to miss: standard screening flows say nothing about radiation. Passing a military screening specification, or even carrying a hardness assured designation, does not establish single event or displacement damage behavior, because those designations often address total dose only.
For destructive single event effects the argument is stronger still, because the variability is not just wide but structured. The commercial MOSFET response variability work found burnout onset voltages in trench devices that were bimodal, which is the shape a small lot sample is least likely to reveal.
What this does not license. Lot traceability tells you that the tested parts and the flight parts came from the same population. It does not tell you that the population is well behaved, which is a separate question answered by sample size and by the shape of the response distribution.
Where it is written down
- NASA/TM-20210018053, COTS considerations and archival data sections and Appendix E. States that process or mask changes can invalidate archival data without changing form, fit and function, that die revisions can occur as often as every 18 months, that non-flight lot data has limited predictive value, that more than three lots are needed to characterize variability, and that standard screening levels do not indicate radiation tolerance.
- JPL Publication 08-10, sample selection section. States that power devices are very susceptible to lot to lot variation, especially at high voltage rating.
Cited as the origin
- George, J. S. et al., 2017, Response Variability in Commercial MOSFET SEE Qualification. IEEE Transactions on Nuclear Science 64(1), 317
- Wheatley, T. H., Wheatley, C. F. and Titus, J. L., 2001, Early lethal SEGR failures of VDMOSFETs considering nonuniformity in the rad-hard device distribution. IEEE Transactions on Nuclear Science 48, 2217
The documents
Standards, test methods and guidelines
Single event and derating documents first, then total dose, then the process-level and terrestrial ones. Access is marked honestly: two of the most cited documents here are behind an ASTM paywall, and the two ECSS standards need a free registration. Several widely quoted revisions are out of date, and those are flagged.
MIL-STD-750, Method 1080 Single-Event Burnout and Single-Event Gate Rupture Test
Scope. Heavy-ion test method for burnout and gate rupture in power transistors, mainly power MOSFETs.
What it requires. Devices are irradiated under stepped drain-source and gate-source bias combinations at a given ion LET. The test is destructive, and a post-irradiation gate stress check follows each step to reveal latent damage.
Why. The rupture threshold depends jointly on the applied bias and the ion LET, because the destructive field in the gate oxide comes from ion-generated carriers on top of the field already there. One fixed bias cannot find the boundary, so the voltage is stepped until the part fails, which is why the method consumes parts.
- A pass at one gate bias says nothing about another. The failure locus moves with VGS, often strongly, and a part qualified at VGS = 0 can fail well below that voltage at a negative gate bias.
- The post-irradiation gate stress step is not optional bookkeeping. It is what separates a part that survived from a part that was damaged and has not failed yet.
ASTM F1192 Standard Guide for the Measurement of Single Event Phenomena Induced by Heavy Ion Irradiation of Semiconductor Devices
Scope. Heavy-ion single-event ground testing of integrated circuits to support on-orbit rate prediction. Excludes protons and neutrons.
What it requires. Defines procedures that produce a plot of cross section against ion LET. Power FETs are explicitly directed to MIL-STD-750 Method 1080 instead.
Why. A rate prediction is an integral of cross section against the mission LET spectrum, so a curve is needed, not a point. The threshold end fixes which ions in the environment matter at all, and the saturated end fixes the rate once they do.
- It is a guide, not a test method. It describes good practice and does not impose pass or fail criteria, so calling a part compliant with F1192 says less than people assume.
- The current edition is F1192-24. A large amount of published work still cites F1192-11(2018).
JESD57 Test Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy Ion Irradiation
Scope. Heavy-ion single-event testing using cyclotron or Van de Graaff beams. Requires delidded devices. Excludes protons and neutrons.
What it requires. Standardizes setup, dosimetry and reporting so that results from different facilities and different operators can be compared.
Why. Package materials degrade and scatter the beam before it reaches the die, so an ion arrives at an unknown energy with an unknown LET. Delidding is what makes the horizontal axis of the cross-section curve mean anything.
- The 2017 revision is the first since 1996, so anything citing plain JESD57 is citing a document a quarter of a century old.
- The JEDEC catalog page currently shows the word Management in the title where every other source, including ESCC 25100, shows Measurement. Measurement appears to be correct.
ESCC Basic Specification No. 25100 Single Event Effects Test Method and Guidelines
Scope. Single-event test requirements for integrated circuits and discrete semiconductors under heavy ions or protons, for European space use.
What it requires. Minimum two to three samples for non-destructive effects and three for destructive effects. About five LET or energy points per test. Beam uniformity within plus or minus 10 percent. Gate rupture testing requires a gate stress check after each irradiation step.
Why. The sample sizes come from Poisson counting statistics, so that a stated confidence level, 95 percent by default, can bound the cross section. The multiple LET points exist because cross section varies over orders of magnitude with LET, so one point cannot be extrapolated.
- The sample counts are minimums for a bounded answer, not a target. Three parts gives a wide interval on any cross section you compute.
- The 95 percent confidence is a default in the specification, not a physical constant. A program can and often should require more.
JPL Publication 08-10 Testing Guideline for Single Event Gate Rupture of Power MOSFETs
Scope. Test methodology, data analysis and derating for gate rupture in power MOSFETs.
What it requires. Recommends multiple stepped drain and gate bias combinations at each LET to map the failure locus, then a design margin below that locus for flight use.
Why. Because the rupture voltage is a function of both biases and of LET, the safe operating area is a surface rather than a number. Testing one corner of it and derating from that corner is how parts get flown at voltages the data never supported.
- It is a NASA guideline, not a consensus standard, so it carries no formal revision control and is cited by date.
NASA EEE-INST-002 Instructions for EEE Parts Selection, Screening, Qualification, and Derating
Scope. Selection, screening, qualification and derating criteria for EEE parts across three reliability levels.
What it requires. Derating limits are distributed across part-family sections, each with its own selection, screening, qualification and derating subsections. They are not collected in a single appendix.
Why. Different part families fail by different mechanisms. Dielectric breakdown, electromigration and wire-bond fatigue have different stress and temperature dependencies, so one generic table would be wrong for most of them.
- People look for the derating tables in an Appendix A. They are not there. Go to the section for the part family.
- These are the derating limits for wear-out and electrical stress. They are not single-event derating limits, and a part meeting them can still be destroyed by one ion.
ECSS-Q-ST-30-11C Space product assurance. Derating, EEE components
Scope. Derating load ratios and application rules for EEE components in space hardware, tailorable per project.
What it requires. Sets maximum stress ratios in voltage, current, power and temperature as fractions of the rated limits, varying by component class, mission duration and mean operating temperature.
Why. Stress-driven wear-out follows acceleration laws in which failure rate climbs steeply with stress ratio and temperature. Derating buys back time to failure so that it exceeds mission life with margin.
- Rev.2 dated 2021 is current. A great deal of practitioner material still cites Rev.1 from 2011.
- As with the NASA document, these ratios address wear-out, not single-event survival. The two derating questions are separate and the single-event one is usually the harsher.
ECSS-Q-ST-60-15C Space product assurance. Radiation hardness assurance, EEE components
Scope. Requirements for a radiation hardness assurance program covering total ionizing dose, displacement damage and single event effects. Excludes spacecraft charging.
What it requires. Requires the mission radiation environment specification to be linked to part-level test levels, margins and analysis, tailorable per project.
Why. The three damage mechanisms are physically unrelated: trapped charge from ionization, lattice displacement from nuclear recoil, and the charge deposited by one ion. A program that qualifies for one has not addressed the others.
- The 2025 Rev.1 is current. Most existing literature cites the 2012 edition, which is superseded.
MIL-STD-883, Method 1019 Ionizing Radiation (Total Dose) Test Procedure
Scope. Cobalt-60 total dose testing of microcircuits, including a low dose rate option, Condition D, for parts suspected of enhanced low dose rate sensitivity.
What it requires. Specifies the bias applied during irradiation, a defined dose rate, and a mandatory room-temperature anneal and rebound measurement afterwards, with an optional elevated-temperature accelerated anneal.
Why. Threshold voltage shift in MOS and gain degradation in bipolar are time and dose-rate dependent, because trapped charge anneals while interface states keep building. A part can look fine at the end of a fast irradiation and then get worse sitting on the bench, which is what the rebound step is there to catch.
- Passing at high dose rate does not bound the low dose rate response of a bipolar part. That is the whole point of enhanced low dose rate sensitivity, and Condition D exists because of it.
- The anneal step is a requirement, not a courtesy. Skipping it can turn a fail into a pass.
ESCC Basic Specification No. 22900 Total Dose Steady-State Irradiation Test Method
Scope. Steady-state cobalt-60 or electron total dose testing of integrated circuits and discrete semiconductors, for evaluation and for lot acceptance.
What it requires. Two dose-rate windows: standard at 0.36 to 180 krad(Si) per hour, and low at 36 to 360 rad(Si) per hour for suspected enhanced low dose rate parts. At least three exposure steps to the specified level, a 24 hour room-temperature anneal under bias, and 168 hours at 100 C under bias.
Why. Same physics as Method 1019 and the same conclusion reached independently: because the damage depends on rate and on time as well as on total dose, the method has to pin the rate and then force the part through the annealing and aging that a real mission would apply slowly.
- The low dose rate window is still roughly a thousand times faster than a real mission. It bounds the effect, it does not reproduce it.
ASTM F1892 Standard Guide for Ionizing Radiation (Total Dose) Effects Testing of Semiconductor Devices
Scope. Sequencing of total-dose hardness tests and data analysis for MOS and bipolar devices below 300 rad(SiO2) per second, using cobalt-60, caesium-137 or low-energy X-ray sources.
What it requires. Frames dose-rate sensitivity as a variable the tester must characterize and manage rather than fixing one approach. States that qualification testing is not required where the needed hardness level is 100 rad(SiO2) or below.
Why. Dose-rate sensitivity varies by technology, so the guide lets the tester choose between bounding a low-rate response with a high-rate test plus anneal, or testing at low rate directly, according to what is known about the device.
- Current edition is F1892-26. Much published work cites F1892-12(2018).
JESD89 Measurement and Reporting of Alpha Particle and Terrestrial Cosmic Ray Induced Soft Errors in Semiconductor Devices
Scope. Terrestrial soft error rate testing and reporting, both real-time and accelerated.
What it requires. A complete assessment needs either full real-time testing or separate accelerated data for the alpha component and the cosmic-ray component. JESD89-3A specifies the beam-accelerated neutron and proton method.
Why. Terrestrial soft error rates are so low that real-time testing needs enormous sample-hours before the answer means anything. Accelerated beam testing compresses years into hours by using a known flux ratio to the terrestrial spectrum.
- This is the terrestrial standard. It is not a substitute for heavy-ion testing for a space part, because the terrestrial spectrum contains nothing like a cosmic-ray iron ion at the top of atmosphere.
NASA-HDBK-4002 Mitigating In-Space Charging Effects, A Guideline
Scope. Spacecraft charging risk assessment and design mitigation, covering surface charging and internal or deep-dielectric charging.
What it requires. Design mitigation guidance separated by charging mechanism, including grounding and bonding, surface resistivity limits and shielding, with updated environment statistics relative to Rev A.
Why. Surface charging comes from low-energy plasma currents on exposed dielectrics and causes arcing through differential charging. Internal charging comes from MeV electrons depositing charge inside insulators faster than it can bleed away. The timescales differ by orders of magnitude, so the mitigations differ too.
- Charging is explicitly outside the scope of the ECSS radiation hardness assurance standard, so a program that has done its radiation analysis has not necessarily done this.
JESD234 Test Standard for the Measurement of Proton Radiation Single Event Effects in Electronic Devices
Scope. Proton single event testing between 40 and 500 MeV. Explicitly excludes low energy protons, where direct ionization dominates, as beyond its scope.
What it requires. Requires a cross section against energy curve rather than a single point, with attention to the knee. Nominal fluence 1e10 protons/cm2 for soft devices and 1e12 for hard ones, minimum five devices for a homogeneous lot, and part replacement at 20 to 50 percent of the established total dose or displacement damage failure level.
Why. The energy window is where indirect ionization dominates, meaning the proton causes a nuclear reaction and the recoil does the damage. Below it, direct ionization takes over and the physics changes; above about 200 MeV the environment contains too few protons for the extra cross section to matter for upset. Destructive effects are the exception, and the standard notes devices where latchup appeared only above 400 MeV.
- A clean proton run is not a heavy ion result. The recoil spectrum from protons in silicon tops out near 15 MeV cm2/mg, so a proton test cannot reach the LET range the cosmic ray environment supplies directly.
- The dose accumulated during the run is not a side effect, it is a competing constraint. At low proton energy the fluence needed for good statistics can exceed the total dose capability of the part.
NASA Proton Single Event Effects Guideline Proton Single Event Effects (SEE) Guideline
Scope. When proton single event testing is required, at what energies, and how the decision follows from existing heavy ion data.
What it requires. Recommends a three point energy curve at 60, 120 and 190 MeV plus or minus 10 MeV. Sets the decision rule from heavy ion data: no proton single event testing needed above a heavy ion threshold of 37 MeV cm2/mg, proton latchup testing required at or below 20, and a rate prediction with a large multiplier in between. Recommends keeping dose accumulated during single event testing below 80 percent of the device tolerance.
Why. The recoil argument is what makes the number specific rather than round: about 37 is treated as approximately the highest LET secondary a 500 MeV proton can produce, so a part immune above it cannot be triggered by anything a proton makes. That is the guideline's own reasoning and it is sound, but it is not the only reason 37 shows up in requirements. The same number is adopted on risk grounds for short missions with modest parts counts, and it appears in vertical power MOSFET requirements for a quite different reason, which is that effective LET is invalid for those devices and a higher number cannot be reached by tilting the part.
- The 37 threshold as used here is about proton induced secondaries. It says nothing about the direct cosmic ray flux above 37, which is what the ECSS immunity figure of 60 and the USAF figure of 75 are for.
- Not every LET 37 requirement traces back to this document. The same number is reached independently from mission risk tolerance and from what a beam line can deliver at normal incidence on a vertical power device. A qualification record that just says 37 does not say which argument was used.
- The guideline notes that parts with high atomic number materials in the active region or packaging can produce higher LET recoils, so the threshold is a screening rule with known exceptions.
Proton Test Guideline Development, Lessons Learned Proton Test Guideline Development, Lessons Learned
Scope. Practical proton test planning: facilities, energies, fluences, dosimetry, degraders, data fitting and the interaction with total dose and displacement damage.
What it requires. Recommends about a hundred events for ten percent counting error, and stopping a null test at 1e11 protons/cm2 or on destruction of the part. Recommends 60 MeV where only one energy is affordable, and the highest available energy for latchup screening. Gives 3e-7 rad(Si) per 30 MeV proton per square centimeter.
Why. Most of the document exists to make the arithmetic explicit. Once you can convert fluence into dose, the tension between the fluence you need for statistics and the dose the part can take stops being a surprise and becomes a test plan input.
- The Bendel relation between proton and heavy ion thresholds is described in the document itself as a crude approximation that should not be used to justify skipping a test. It is regularly cited as though it were the opposite.
- It predates the low energy proton direct ionization literature entirely, so its treatment of low energy protons covers photodetectors and optocouplers rather than scaled digital parts.
NASA/TM-20210018053, NESC-RP-19-01489 Avionics Radiation Hardness Assurance (RHA) Guidelines
Scope. End to end radiation hardness assurance for avionics: environment definition, failure mechanisms, part categorization, testing strategy, mitigation and the use of archival data.
What it requires. Defines radiation design margin as failure level over specification level and drives part categorization from it, without prescribing a numeric target. Sets expectations for rate prediction accuracy, for the use of heritage and similarity data, and for sample sizes in the presence of badly behaved response distributions.
Why. It is the most candid of the guidance documents about the limits of its own methods. It describes the design margin approach as ad hoc and capable of both under and over specifying, and its appendix on sampling explains why a small clean sample from a bimodal population is not evidence.
- It is a guideline and a technical memorandum, not a NASA standard, so it does not levy requirements by itself.
- The statement that standard screening flows do not indicate radiation tolerance is easy to skim past and is one of the most consequential sentences in the document.
DTRA-TR-23-43 Pulsed-Laser Single-Event Effects (PL SEE) Testing, A Practical Desk Reference
Scope. Planning and executing pulsed laser single event campaigns, including single photon and two photon absorption, sample preparation and the interpretation of laser results.
What it requires. Frames the technique as complementary to broad beam testing and states plainly that heavy ion and proton data are still required for rate prediction in most cases.
Why. A laser deposits charge by photon absorption rather than by a charged particle track, so there is no first principles conversion from pulse energy to LET. What the laser can do that a broad beam cannot is tell you where on the die the sensitivity is, which is a different and often more actionable answer.
- Laser equivalent LET is a calibration, not a measurement. Establishing it requires heavy ion data on the same part, which is the thing the laser was supposed to replace.
- Laser work is almost always at normal incidence because of the objective working distance and refraction at the die surface, so angular studies are not available from it.
MIL-HDBK-814 Ionizing Dose and Neutron Hardness Assurance Guidelines for Microcircuits and Semiconductor Devices
Scope. Piece part hardness assurance for total ionizing dose and neutron displacement damage: design margin, lot definition, sample size, overtest and end point determination.
What it requires. Recommends a minimum design margin of 2 to 3, a nominal ten devices per lot rising to thirty when the data are widely scattered and never below five, and gives the statistical relation behind overtesting.
Why. It is the document that turns hardness assurance from a set of habits into arithmetic. The design margin recommendation follows from the observation that a margin of one implies about a 50 percent survival probability, and the overtest relation shows exactly what dose margin buys in sample size.
- It is thirty years old and predates enhanced low dose rate sensitivity as a named phenomenon, so its total dose guidance needs to be read alongside the current Method 1019.
- Its design margin numbers are frequently quoted as though they applied to single events. They were written for total dose and neutron damage, where a failure level distribution exists to have a margin against.
DNA-H-95-61 Transient Radiation Effects on Electronics (TREE) Handbook
Scope. Radiation effects on semiconductor devices and materials, hardening technology, hardness assurance and testing, for both nuclear weapon effects and the natural space environment.
What it requires. Not a requirements document. It sets out the design margin breakpoint method with its 2, 10 and 100 categorization, the bremsstrahlung and shielding physics, the cosmic ray LET spectrum and the dose enhancement problem.
Why. It was written to be the reference a hardening engineer works from, so it explains rather than specifies. It is where several numbers that appear as bare requirements elsewhere are actually derived, including the design margin breakpoints and the atomic number scaling of bremsstrahlung production.
- Its emphasis on weapon effects, dose rate and prompt phenomena is not relevant to most space work, and skimming it for space content means skipping a great deal.
- It is from 1995, so anything it says about device technology is three decades out of date even though the physics is not.
The beams
Test facilities
Heavy-ion and proton test facilities, with the parameter that decides whether a facility can test your part at all: ion range in silicon. A high LET beam that stops before it reaches a buried well or the drift region of a power device gives a falsely reassuring answer, which is why energy per nucleon appears here next to LET. Operational status was checked against each facility's own pages in September 2026 and is identified, including cases where it could not be confirmed. This matters more than usual right now: one major facility is shut for the whole of 2026, and several widely cited sites have closed or changed identity in the last few years.
Texas A&M University Cyclotron Institute, Radiation Effects Facility
Worth knowing. The workhorse for routine single event work in the United States, roughly 10,000 beam hours a year, with both cyclotrons and mature degrader tooling. Heavily oversubscribed, so book far ahead.
Michigan State University, K500 Chip Testing Facility (KSEE)
Worth knowing. The most useful new capacity in years, and it accepts test boards built to the Texas A&M and Berkeley mounting patterns. Note this is the refurbished K500, not the FRIB linac.
Michigan State University, FRIB Single Event Effects Facility (FSEE)
Worth knowing. High penetration and an unusual pulsed beam structure. Availability, not capability, is the constraint. The former NSCL coupled cyclotron facility closed after its last physics run in May 2022.
Lawrence Berkeley National Laboratory, 88-Inch Cyclotron, BASE facility
Worth knowing. The only one of the major sites with heavy ion, proton and neutron capability in one place, including an 8 to 40 MeV neutron beam. Site of the first single event tests in 1979.
Brookhaven National Laboratory, NASA Space Radiation Laboratory (NSRL)
Worth knowing. An option for high-penetration beams or large-area exposures; less suited to routine cross-section sweeps.
Brookhaven National Laboratory, Tandem Van de Graaff SEU Test Facility
Worth knowing. Good for shallow junction and legacy parts. The short range is a real limitation for modern deep well parts and power devices, and NASA's own facility assessment says so plainly.
TRIUMF Proton and Neutron Irradiation Facilities (PIF and NIF)
Worth knowing. The single most consequential status item on this page. If your test plan assumes TRIUMF in 2026 or in the first half of 2027, it needs replanning now.
University of California Davis, Crocker Nuclear Laboratory
Worth knowing. A dependable mid energy tunable proton source. Protons only.
Paul Scherrer Institute, PIF and OPTIS
Worth knowing. An ESA designated European component irradiation facility. Day shifts go to biomedical use, so electronics work runs mostly at nights and weekends.
University of Jyvaskyla, RADEF
Worth knowing. The best published range and LET documentation of any facility here, which matters when a test report has to defend its horizontal axis.
PARTREC, AGOR cyclotron
Worth knowing. Use the current name when booking. Anyone searching for KVI-CART and concluding it has gone is reading a stale record.
Universite catholique de Louvain, Cyclotron Resource Centre
Worth knowing. A convenient European multi particle site. The 9.3 MeV per nucleon heavy ion energy gives limited range, so check the range tables before using it on thick or power parts.
Los Alamos Neutron Science Center, ICE House and ICE-II
Worth knowing. The reference facility for atmospheric neutron single event work. The proposal process is heavier than a commercial booking, so allow for it.
ChipIr, ISIS Neutron and Muon Source
Worth knowing. Purpose built for electronics rather than shared with physics users, and the flood beam mode makes whole board and avionics box testing practical.
iThemba LABS
Worth knowing. Listed because it exists and does applied radiation damage work. Confirm the service directly before planning around it.
HIMAC, National Institutes for Quantum Science and Technology
Worth knowing. The nearest Japanese equivalent in role to the Brookhaven space radiation laboratory. Verify current terms directly.
Northwestern Medicine Proton Center
Worth knowing. Access at any proton therapy center is secondary to patient treatment and can change with hospital management. Treat it as useful but not guaranteed.
Massachusetts General Hospital, Francis H. Burr Proton Therapy Center
Worth knowing. Historically valuable for high energy large area exposure. Verify current availability before relying on it.
Still listed in places, no longer available
Indiana University Cyclotron Facility. Closed in 2014. It was the flexible United States proton workhorse and nothing has replaced its capacity.
ProVision CARES Proton Therapy Center, Knoxville. Closed 1 February 2022 after a change of management. It had been the most used United States site for electronics proton testing.
NSCL Coupled Cyclotron Facility, Michigan State. Closed after its last physics run in May 2022 and superseded by FRIB. The K500 was later refurbished as a separate chip test beamline; the K1200 is not confirmed to be in service for anything.
The data
Radiation test data sources
Sources of part-level radiation test data. This includes sources you cannot use: a database that needs a CERN account, a government library open only to vetted stakeholders, proceedings behind an IEEE paywall. They are listed because access restrictions can explain gaps in a search for radiation data.
Beam facilities and commercial databases in this list
Beam facilities are listed too, marked as such, because they are frequently mistaken for data repositories: the results of a campaign belong to whoever paid for it. Several specialist commercial databases now exist alongside the agency ones, which is a real change in the last few years: a decade ago the only route to radiation data on a commercial part was to test it yourself or find a paper. Their coverage of parts nobody else tests is genuinely useful, and the usual caution applies, which is to check the failure definition and the test protocol behind a number before adopting it.
NASA GSFC REAG Radiation Test Database
Per-part radiation test reports generated by the group, covering heavy-ion single event effects, proton displacement damage and total dose.
Worth knowing. The single most useful free source for flight-relevant parts. The results table loads by script, so the record count and any bulk export could not be confirmed.
NASA GSFC REAG Publications Database
Searchable bibliography of the group's radiation effects papers and conference presentations.
Worth knowing. A publication index, not part-level data. Use the test database above for actual results.
NASA GSFC REDW Compendium papers
Annual free compendium of recent radiation effects test results for parts the group tested, confirmed through 2024.
Worth knowing. Covers only the parts that group tested each year, not the whole data workshop.
NASA NEPP publications and workshop archive
Publication browser plus a year-by-year workshop presentation archive confirmed live from 2010 to 2025.
Worth knowing. Covers all parts and packaging topics, not only radiation, and workshop items are slides rather than validated reports.
NASA Technical Reports Server
General aerospace repository of over 500,000 citations. A radiation testing keyword search returned roughly 2,500 hits.
Worth knowing. A general search engine, not a radiation database. Results need heavy manual filtering.
ESA Radiation Database
Test reports for total dose, displacement damage and single event effects on EEE components tested by ESA or under ESA contract. Over 180 report entries shown.
Worth knowing. Registration is aimed at organizations in ESA member states. Note the name collision: ESARAD is also a module of an unrelated thermal analysis suite.
ESCIES radiation test reports portal
Portal linking to the ESA Radiation Database, ESA technology study reports, external company reports and an archive up to 2004.
Worth knowing. Mainly a set of links rather than a database in its own right. It is also where the ESCC specifications themselves live.
CERN RADWG radiation test database
Test results for over 400 component references, mostly from 200 MeV proton testing, used by CERN equipment groups.
Worth knowing. Publicly described but not publicly accessible. Unusable without a CERN account.
CERN R2E project site
Public overview of CERN radiation testing with links to papers and reports on radiation levels and effects.
Worth knowing. An information and bibliography site. The actual results sit behind the RADWG login.
RADNEXT Zenodo community
Transnational access summary reports and papers from funded test campaigns, roughly 234 records when checked.
Worth knowing. Individual PDF reports rather than a structured database. Coverage lags because researchers have months to upload.
RADNEXT facility access program
Not a data repository. Funds free beam time across more than 50 partner facilities by competitive proposal.
Worth knowing. Listed here because it is often mistaken for a database. It is how you get beam time, not how you get data.
CERN irradiation facilities database
Directory of about 228 irradiation facilities worldwide with contacts, beam types and access information.
Worth knowing. A directory of where to test, not of test results. Genuinely useful when planning a campaign.
PMPedia
Crowd-sourced repository of alternate-grade and COTS parts with per-part radiation test summaries and downloadable reports.
Worth knowing. Crowd-sourced, so coverage is uneven. Valuable precisely because it covers COTS parts the formal databases do not.
JAXA Space Environment and Effects System
Space environment data and effects models including upset, total dose, solar cell degradation and charging.
Worth knowing. Oriented to environment and effects models rather than a part-level test archive. Registration terms for non-JAXA users are not stated publicly.
IEEE Radiation Effects Data Workshop proceedings
The annual workshop record: radiation test papers on real parts, going back to the early 1990s. The backbone of the public literature.
Worth knowing. A proceedings archive of individual papers, not a queryable part database. Institutional access changes the economics completely.
RADECS conference proceedings
The European counterpart to the data workshop, running since the late 1980s.
Worth knowing. Note that radecs.org without the word association currently resolves to unrelated content and is not the real site.
Zero-G Radiation Assurance database
Dedicated radiation test data for mostly COTS and automotive-grade parts compiled from two decades of papers and reports, with prediction tools.
Worth knowing. A specialist radiation data vendor rather than a general parts aggregator. Its own pages give conflicting record counts, 6,000 on one and over 11,000 on another.
JPL Radiation Effects Database
Radiation effects test data on parts and systems from JPL-led campaigns across heavy-ion, proton, neutron, electron and total dose environments. The stated successor to the legacy RadCentral database, developed with support from the NASA Parts Evaluation and Assessment Laboratory.
Worth knowing. New and still thin. The site itself says reports are released on a rolling basis as they clear public distribution review, so expect gaps rather than coverage. Worth re-checking periodically rather than writing off.
The Radiation Team parts database
Browsable index of parts for which they hold radiation data, combining publicly documented results with their own internal campaign reports. Searchable by part number, manufacturer, type or specification, with category and specification filters.
Worth knowing. The browser tells you whether a part has been characterized, not what the result was. You build a parts list and their engineering team follows up with what is available and at what price. Useful as a fast existence check before committing a part to a design.
Nucleon parts database
Commercial radiation test database aimed at COTS parts for spacecraft design, alongside test services. The company also operates a marketplace for buying and selling radiation test reports.
Worth knowing. Their high-throughput commercial power MOSFET screening work was presented at the 2024 IEEE Radiation Effects Data Workshop, so the method is documented in the open literature even where the database is not. As with any single-source screen, check the test protocol against your own definition of failure before adopting the numbers.
Accuris Engineering Workbench
Standards library plus part lifecycle, compliance and sourcing records. Via Haystack Gold, defense procurement data that may reference hardness-assured device classes.
Worth knowing. Public pages never explicitly claim radiation test data. Useful for standards access and procurement status, not as a radiation source.
SiliconExpert
Component lifecycle, compliance, obsolescence and bill-of-materials risk data.
Worth knowing. No public page mentions radiation hardness. Listed so that its absence from the radiation picture is explicit.
Z2Data
Component parametric, lifecycle and compliance data, with automotive qualification and military screening status.
Worth knowing. Markets military screening and qualified-parts tracking, but no page found claims radiation test data as a feature.
Microchip radiation and reliability data
Total dose, single event and transient test reports for radiation-tolerant FPGA parts. Lot-specific total dose reports ship with flight orders.
Worth knowing. Limited to their FPGA and radiation-tolerant line.
Texas Instruments space products radiation reports
Per-part total dose and hardness-assurance reports and single-event characterization for space-grade parts, as free PDFs.
Worth knowing. Among the most open vendor libraries. Production lot acceptance summaries still ship only with product orders.
Renesas rad-hard test reports
Per-part total dose, low dose rate, single event and neutron displacement damage reports for roughly 300 Class V products.
Worth knowing. Limited to their own rad-hard line, but deep within it.
Analog Devices space product test reports
Per-part total dose at high and low dose rate, low dose rate sensitivity and latchup reports for space-grade analog and power parts.
Worth knowing. Reports are generic or lot-representative, not a guarantee for a specific wafer lot.
Frontgrade Gaisler product radiation reports
Per-product radiation summary reports covering total dose, latchup and upset for processors such as the GR740.
Worth knowing. Limited to their processor line. Some documents in the download tables require a contact or password.
Infineon IR HiRel radiation data
Total dose and single event reports for rad-hard power devices. Selection guides are public, the reports are not.
Worth knowing. The page itself states that full test reports need an account.
STMicroelectronics space products documentation
Qualitative radiation specifications in datasheets and application notes. No downloadable per-part reports found publicly.
Worth knowing. The least self-service of the major vendors checked.
VORAGO Technologies documentation
White papers on their hardening process plus one detailed third-party test report for a specific part.
Worth knowing. Only one detailed per-part report is publicly posted.
Strategic Radiation Hardened Electronics Council parts library
Planned multi-agency repository consolidating single-event, total dose and displacement damage data across government programs.
Worth knowing. Known from a 2022 briefing describing a data collation phase. Current status not found.
Defense Technical Information Center
Search portal for defense-funded technical reports, including historical radiation hardness assurance work among vast unrelated content.
Worth knowing. Not curated for radiation. Relevant reports are scattered and often decades old.
Boeing Radiation Effects Laboratory
Commercial radiation testing services covering total dose, dose rate, displacement damage and single event effects.
Worth knowing. A testing service, not a published dataset.
Other prime contractors
No dedicated public radiation database found for any of these. Individual engineers occasionally co-author conference papers.
Worth knowing. Radiation data at the primes is a program deliverable, not a publication. Listed so the gap is explicit.
Vanderbilt Institute for Space and Defense Electronics
Research institute with on-site total dose irradiators. Single-event work runs at partner cyclotrons.
Worth knowing. A research and test services provider, not a public repository.
Texas A&M Cyclotron Institute Radiation Effects Facility
Heavy-ion and proton beam facility. Public downloads are technical references such as LET and range plots.
Worth knowing. A beam facility. Users own their data and the facility does not publish it.
Berkeley Accelerator Space Effects Facility
Heavy-ion, proton and neutron beam facility. Site hosts technical reference material such as Bragg curves.
Worth knowing. A beam facility, not a data repository, despite its central place in single-event history.
RADEF Radiation Effects Facility
Proton, heavy-ion and gamma beams. Holds status as an ESA European Component Irradiation Facility.
Worth knowing. Test reports go to the sponsoring customer, often ESA, and reach the public only through the ESA database or papers.
UCLouvain Cyclotron Resource Centre
Heavy-ion, proton, neutron and cobalt-60 lines for single event, total dose and displacement damage testing.
Worth knowing. A beam facility. Results belong to the customer.
GANIL
Heavy-ion beams for single event testing of electronic components.
Worth knowing. A beam facility. Data generated during a session is not published by the laboratory.
Corrections are welcome through the community forum or by getting in touch. If a revision has moved on or an access term has changed, say so and it will be fixed. Nothing on this page reproduces the content of a paywalled document; the requirement and reasoning summaries are written from the publicly stated scope and from standard practice.