TID Lot Acceptance Report Generator

Help & User Guide

Preliminary analysis aid. Check the result against your own analysis and, where needed, a test on the intended part. Full disclaimer.

1. What it calculates

From the parameter readings of a total dose lot acceptance test, one table per parameter with units down the side and dose steps across the top, it computes at every step the sample mean, standard deviation, the exact one sided tolerance factor KTL for the sample size at that step, the bounds x̄ ± KTL s, and a pass or fail against the limits; plots every unit, the mean and the bounds against dose with the limit line; states the first dose step at which the bound crosses the limit and the verdict at your specification dose; and produces a report you can print to PDF or download as Markdown, with the statistics as CSV and each plot as SVG. The default criterion is P = 0.99 of the lot with γ = 0.90 confidence.

In one line: paste the data, set the limits, get the KTL report.

2. Inputs

3. Calculation

4. Assumptions

5. Implementation notes

6. Limitations

7. References

MIL-HDBK-814, Ionizing Dose and Neutron Hardness Assurance Guidelines for Microcircuits and Semiconductor Devices, 1994. · MIL-STD-883 Test Method 1019, Ionizing Radiation (Total Dose) Test Procedure, current revision. · ESCC Basic Specification 22900, Total Dose Steady-State Irradiation Test Method, Issue 5. · Odeh, R. E. and Owen, D. B., Tables for Normal Tolerance Limits, Sampling Plans and Screening, 1980. · Natrella, M. G., Experimental Statistics, NBS Handbook 91, 1963. · Ladbury, R. and Gorelick, J. L., Statistical Methods for Large Flight Lots and Ultra-High Reliability Applications, IEEE Transactions on Nuclear Science 52(6), 2630, 2005.

Back to the tool · Total Dose Hardness Priors · Why 1.5 times the specification dose